Section 4 Service Procedures
WARNING
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
•Disconnect electrical power to the
•Close the gas
•Never start the
•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the
W461R1
Refer to Figure 7.
REMOVAL
a.Turn off power to the machine.
b.Remove the top cover. Refer to Paragraph 19.
c.Using a 10 mm nut driver, remove the screws that attach the AC drive box cover to the AC drive box.
d.Disconnect the wiring to the AC drive fan.
e.Remove the AC drive box cover.
f.Label and remove the wires from the AC drive.
g.Using a 5/16 inch nut driver, remove the nuts and screws that attach the AC drive to the AC drive box.
h.Remove the AC drive from the AC drive box.
INSTALLATION
a.Position the AC drive within the AC drive box.
b.Using a 5/16 inch nut driver, replace the screws and nuts that attach the AC drive to the AC drive box.
c.Reconnect the wires to the AC drive.
d.Reconnect the wiring to the AC drive fan.
e.Position the AC drive box cover.
f.Using a 10 mm nut driver, replace the screws that attach the AC drive box cover to the AC drive box.
g.Replace the top cover. Refer to Paragraph 19.
h.Turn on power to the machine.
i.Calibrate the machine. Refer to the “Calibration of the Machine” section in the programming manual supplied with your machine.
j.Test the basket rotation speeds by starting Cycle 39 and advancing to step 28. Refer to Table 1. Check steps 28 through 31 for the following basket RPM’s.
NOTE: To check the RPM’s, press the “Display Temp” keypad.•Spin 1: 500 RPM’s
•Spin 2: 650 RPM’s
•Spin 3: 800 RPM’s
•Spin 4: 1000 RPM’s
100and• Spin 1: 500 RPM’s
• Spin 2: 650 RPM’s
• Spin 3: 800 RPM’s
• Spin 4: 800 RPM’s
•Spin 1: 500 RPM’s
•Spin 2: 650 RPM’s
•Spin 3: 750 RPM’s
•Spin 4: 750 RPM’s
AC Drive
Box
AC | CFS12S |
Drive | AC Drive |
| Fan |
Figure 7
70 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9001900 |