Section 4 Service Procedures

WARNING

To reduce the risk of electrical shock, fire, explosion, serious injury or death:

Disconnect electrical power to the washer-extractor before servicing it.

Close the gas shut-off valve to the washer-extractor (when applicable) before servicing it.

Never start the washer-extractor with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the washer-extractor is properly grounded.

W461R1

Deflection

Span Length

P044IE3A

Figure 11

27.WATER VALVE REMOVAL AND REPLACEMENT

Refer to Figure 12.

REMOVAL

a.Turn off power to the machine.

b.Remove the top cover. Refer to Paragraph 19.

c.Disconnect the water supply hose from the water valve.

d.Loosen the clamps that attach the hoses to the top of the water valve.

e.Disconnect the hoses from the top of the water valve.

f.Remove the screws that attach the water valve to the upper rear panel.

g.Remove the water valve.

REPLACEMENT

a.Position the water valve on the upper rear panel.

b.Replace the screws that attach the water valve to the upper rear panel.

c.Reconnect the hoses to the top of the water valve.

d.Tighten the clamps that attach the hoses to the top of the water valve.

e.Reconnect the water supply hose to the water valve.

f.Replace the top cover. Refer to Paragraph 19.

Water

Valve

Upper Rear

Panel

Water Supply

Hose

CFS15S

Figure 12

9001900

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT