Section 3 Troubleshooting
2.The
Is |
|
|
the main | NO |
|
power circuit |
| Turn on the main power |
breaker |
| circuit breaker. |
on? |
|
|
YES |
|
|
Is 1 there voltage
coming out of the NO main power block
between wires L2 (blue) and L1 (brown)?
YES
2
Is there
Voltage (120 NO Volts) into
and out of the
3.15Amp
fuse?
YES
Is there | 3 | |
| ||
voltage (120 | NO | |
Volts) into and | ||
| ||
out of both sides of |
| |
the |
| |
switch? |
|
Check the main power circuit breaker and power to the machine.
Replace the 3.15 Amp fuse.
Reset and return (either by pulling or by twisting and pulling) the
YES
|
| Is there | 4 |
|
|
| |
|
| voltage (220 |
|
|
| Volts) between the | NO |
|
| L2 (blue) and L1 (brown) |
|
|
| wires going into the |
|
|
| power connector |
|
|
| on the main |
|
|
| board? |
|
|
| YES |
|
|
| Is the | 5 |
|
| 125 mA fuse |
|
| YES | above the power | NO |
| connector on the | ||
Replace the 125 mA fuse. |
| main board blown? |
|
| An ohms test is the |
| |
|
|
| |
|
|
| |
|
| recommended |
|
|
| check for |
|
|
| the fuse. |
|
Check the L2 (blue) and L1 (brown) wires between the
Check the cable between the main board and the keypad for any loose or broken connections. repair or replace the cable as needed.
6
If the cable is intact, please contact Alliance Laundry Systems’ customer service department before replacing the main board, keypad or cable between the main board and keypad.
CFD4S
14 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9001900 |