Section 3 Troubleshooting
13. MACHINE DID NOT FILL ALARM ANALYSISIs there water coming in | NO | |
through the water supply |
| |
| ||
lines? |
| |
| YES |
|
|
| |
|
|
|
1 |
|
Check the main water valve
|
|
|
|
|
| IS | ||
|
|
|
|
|
| there voltage | ||
|
|
|
|
|
| (220 Volts) at the | ||
|
|
|
|
|
| respective water | ||
|
|
|
|
|
| valve that should | ||
|
|
|
|
|
| be turning | ||
|
|
|
|
|
| on? | ||
|
|
|
|
|
|
| NO | |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
| 2 | |||
|
|
|
|
|
| Is | ||
|
|
|
|
|
| there | ||
|
|
|
|
|
| continuity | ||
|
|
|
|
|
| between the wire | ||
|
|
|
|
|
| from the main | ||
|
|
|
|
|
| board to the | ||
|
|
|
|
|
| water valve? | ||
|
|
|
|
|
|
| NO | |
|
|
|
|
|
|
| ||
| Replace the main board. |
|
|
|
| |||
3 | ||||||||
|
|
|
|
| ||||
|
| YES | ||||||
|
| |||||||
|
|
|
|
| ||||
4 |
|
|
|
| Is | |||
|
|
|
|
|
| |||
|
|
|
|
|
| there voltage (220 | ||
|
|
|
|
|
| Volts) between the | ||
| Is |
| drain wires on the main | |||||
| the water plug |
| board? | |||||
| harness | NO | ||||||
|
| For example, for the | ||||||
| connector on the |
| ||||||
| main board |
| cold fill valve, is there | |||||
| intact? |
| voltage between the | |||||
|
|
|
|
|
| gray (cold fill) and blue | ||
|
|
|
|
|
| (common) wire? | ||
|
| NO |
|
|
| |||
|
|
|
|
| ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
| Replace the water valve |
|
|
|
| |||
| wiring harness. |
|
|
|
| |||
|
|
|
|
|
|
|
|
YES
Replace the water valve.
YES
Replace the main board.
YES
Replace the water valve.
CFD1989S
52 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 9001900 |