Section 3 Troubleshooting

15.AUTOMATIC SUPPLY DISPENSER ANALYSIS Run Program 38.

 

Cycle 38

 

 

 

Cycle 38

 

 

Supply Setup

 

 

 

Supply Setup

 

 

 

 

 

 

 

 

Step

Description

Min:sec

 

Step

Description

Min:sec

 

 

 

 

 

 

 

1

Warm Fill to Low Level

5:00

 

8

Warm Fill to Low Level

5:00

 

 

 

 

 

 

 

2

Supply 1

2:00

 

9

Supply 6

2:00

 

 

 

 

 

 

 

3

Supply 2

2:00

 

10

Supply 7

2:00

 

 

 

 

 

 

 

4

Supply 3

2:00

 

11

Supply 8

2:00

 

 

 

 

 

 

 

5

Supply 4

2:00

 

12

Supply 9

2:00

 

 

 

 

 

 

 

6

Supply 5

2:00

 

13

Wash 1 18/3 (80°F)

0:30

 

 

 

 

 

 

 

7

Drain 1

1:00

 

14

Drain 1

1:00

 

 

 

 

 

 

 

Run the cycle and, with the respective supply on the main display, refer to the following chart for the function that should be occurring:

SupplyFunction

 

Voltage

 

 

 

 

1

Turns on the water valve in compartment A of the

N/A

 

 

supply box.

 

 

 

 

 

 

2

Turns on the water valve in compartment B of the

N/A

 

 

supply box.

 

 

 

 

 

 

3

Turns on the water valve in compartment C of the

N/A

 

 

supply box.

 

 

 

 

 

 

4

Activates supply relay 1. Visibly inspect the relay to

220

Volts between terminals 1 and14

 

see if it is closing and check for voltage.

 

 

 

 

 

 

5

Activates supply relay 2. Visibly inspect the relay to

220

Volts between terminals 3 and14

 

see if it is closing and check for voltage.

 

 

 

 

 

 

6

Activates supply relay 3. Visibly inspect the relay to

220

Volts between terminals 5 and14

 

see if it is closing and check for voltage.

 

 

 

 

 

 

7

Activates supply relay 4. Visibly inspect the relay to

220

Volts between terminals 7 and14

 

see if it is closing and check for voltage.

 

 

 

 

 

 

8

Activates supply relay 5. Visibly inspect the relay to

220

Volts between terminals 9 and14

 

see if it is closing and check for voltage.

 

 

 

 

 

 

9

Activates supply relay 6. Visibly inspect the relay to

220

Volts between terminals 11 and14

 

see if it is closing and check for voltage.

 

 

 

 

 

 

60