Section 4
Service Procedures
WARNING
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
•Disconnect electrical power to the
•Close the gas
•Never start the
•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the
W461R1
Refer to Figure 3.
REMOVALa.Turn off power to the machine.
b.Using a 10 mm socket wrench, remove the screws that attach the top cover to the machine.
c.Lift the top cover off of the machine.
REPLACEMENTa.Replace the top cover onto the machine.
b.Using a 10 mm socket wrench, replace the screws that attach the top cover to the machine.
Top
Cover
CFD6S
Figure 3
REMOVAL
a.Turn off power to the machine.
b.Remove the top cover. Refer to Paragraph 19.
c.Disconnect the ribbon cables from the keypad.
d.Using a 5.5mm nut driver, remove the nuts that attach the keypad to the control panel.
e.Remove the keypad.
INSTALLATIONa.Position the keypad.
b.Using a 5.5 mm nut driver, replace the nuts that attach the keypad to the control panel.
c.Reconnect the ribbon cables to the keypad.
d.Replace the top cover. Refer to Paragraph 19.
e.Turn on power to the machine.
f.Test the keypad’s buttons by pressing each one and checking for a single beep.
Ribbon
Cables
Keypad
CFD9S
Control
Panel
Figure 4
9001900 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 65 |