Features in 291-05

 

 

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

Module

Level

Description

AR400

AR7x5

AR7x0S

 

Rapier i

AT8800-

AT-8600

 

AT-8700XL

x90048-

AT-9900

AT-9800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00016459

Core

-

This enhancement disables CPU fan monitoring on AT-8948 switches. Monitoring

-

-

-

 

-

-

-

 

-

Y

-

-

 

 

 

the fan is unnecessary unless an accelerator card is installed on the switch, so

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disabling monitoring reduces the number of messages that the switch displays

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and logs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To enable monitoring, use the command:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

enable cpufanmonitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To disable it again, use the command:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disable cpufanmonitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When monitoring is enabled, the command show system displays the CPU fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

status in the entry labelled “Main fan”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00016523

SNMP

-

This enhancement enables you to specify whether SNMP adds 0x00 padding

Y

Y

Y

 

Y

Y

Y

 

Y

Y

Y

Y

 

 

 

when the most significant 9 bits of an object’s value are all 1, or whether the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

encoding follows the ASN.01 BER rule, which cuts off the most significant byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of 0xff. This setting has an impact on all integer type MIB objects, including 32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bit and 64 bit counter objects.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To add the padding, use the command:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

set snmp asnberpadding={onyestrue}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For examples, see “SNMP ASN.01 BER Padding—CR00016523” on page 99.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 