E Q U I P M E N T P R O T E C T I O N

NXA-UPS9510

FG678

A 19" Rack Mount surge protected UPS designed for AMX NetLinx systems. The UPS has a capacity of 1000/650 VA/W with a battery maintaining a recharge time of 5 hours (to 90% capacity). The unit comes with 8 NEMA 5-15R.

FEATURES

The NXA-UPS9510 has multiple voltage selections using line interactive technology.

The unit features True Sine Wave output, Smart Battery Management and AVR (Automatic Voltage Regulation) - all in a compact design (only 2 units high).

Capacity (VA/W): 1000/650

Input voltage range: 75-150 volts or 150-300 volts

Frequency range: 45-55Hz or 55-65Hz, auto-select

Output voltage on unit: 100/110/120/127 Volts ± 10% or 208/220/230/240 Volts ± 10%

Output voltage (on battery): 100/110/120/127 Volts ± 10% or 208/220/230/240 Volts ± 10%

Output frequency (on battery): 60/50Hz ± 1Hz

Output waveform: Sinewave

Battery Type: 12V / 7.2 AH x 4 (sealed maintenance free)

Recharge Time: 5 hours to 90% capacity

DIMENSIONS

17" x 19.6" x 3.5" (4.30 cm x 6.25 cm x 8.8 cm)

WEIGHT

72.75 lbs (21 kgs)

NXA-MPS16F

FG677

A 19" rack-mount silicon avalanche diode, NXA-MPS16F surge protection system designed for AMX NetLinx systems for data and communications. The unit mounts flush in the rack and provides 32 easy to reach ports for 16 In and Out connections. These units provide surge protection for all communications and DC power provided through the RJ-45 connections. Port number 1 is a protected Ethernet port and port numbers 2 through 16 are for the NetLinx communications protocols.

FEATURES

The rack mount protector is compact with in-line insulation.

Multiple interface options are available.

SPECIFICATIONS

Port Protection:

Ethernet Port #1 - All pins protected 7.5 Vpk 60A 10x1000 ms

NetLinx Ports #2-16 - All pins protected 7.5 Vpk 60A 10x1000 ms

DV Voltage pins 4-5 15 Vpk 206A 10x1000 ms

Dimensions: 3.5" x 19" x 0.875" (8.89 cm x 48.26 cm x 2.22 cm)

Temperature: -22° - 149° F (-30° - +65° C)

NXA-TSJ45

FG676

An individual plug-in silicon avalanche diode surge protector designed for AMX NetLinx systems. The unit mounts on the end of individual nodes for surge protection. These units provide surge protection for all communications and DC power provided through the RJ45 connection.

FEATURES

All eight wires are surge protected.

The NXA-TSJ45 protectors should be installed on both ends of the data cable for the most effective protection.

If a NXA-MPS16F patch panel is utilized, then it is recommended that one NXA-TSJ45 be utilized on each node on the other end for complete line protection.

Voltage Protection Level: All data pins are protected at 7.5 Vpk

DC voltage, pins 4-5 at 15 Vpk

Peak Pulse Current (10/1000ms):

Data: 60A 10 x 1000 ms

DC Power: 206A 10 x 1000 ms

Dimensions: 3.6" x 1.47" x 0.925" (9.14 cm x 3.73 cm x 2.35 cm)

Temperature: -22° - 149° F (-30° - +65° C)

CONFIDENTIAL INFORMATION © 2003 AMX Corporation. All rights reserved. AMX and the AMX logo are all trademarks of AMX Corporation.