A X C E S S P R O C E S S O R C A R D S

A X C E S S P R O C E S S O R C A R D S

AXC-EM

Enhanced System Master Card

FG711

Fully compatible with Axcess software, the AXC-EM manages system operation and executes control system programs. This Enhanced Master Card can coordinate the activities of up to 255 different pieces of equipment, such as other control cards, bus controllers and various input devices. These include AMX Tiltscreens, touch panels, softwire panels, wireless receivers and custom panel interfaces.

APPLICATION

Provides AXCESS Master processing and features to CardFrame

PROCESSOR

Motorola 16-bit M68340

MEMORY

Standard – 64KB; Optional – 256KB

INCLUDES

One status LED for power and AXLink operation

Master Program Port, male DB-9 connector

Setup switch for Master Port baud rate, parity, stop bits, and data bits

AXC-S

CardFrame Server Card

FG705

APPLICATION

Manages communication among control cards in CardFrame

PROCESSOR

Motorola MC68HC705

INCLUDES

One status LED for power and AXLink operation

One front-mounted AXLink jack for local testing of panels and Bus Controllers

Setup switch to set starting device number to CardFrame

A X C E S S D A T A C O N T R O L C A R D S

AXC-232

RS-232/422/485 Interface Card

FG725

Many audiovisual and computer based devices can be controlled remotely by using RS-232 or RS-422 commands. The AXC-232 RS-232/422/485 Interface Card can generate a virtually unlimited number of product/function commands as they are programmed into the AXC-M Master Card. As needs and technology changes, existing cards can be reprogrammed or new cards added, one for each device.

APPLICATION

RS-232/422/485 data control transmit and receive

CONTROL PORT

RS-232, RS-422/485 data port (300-38,400 baud)

INCLUDES

Two status LED indicators for transmit and receive

One setup switch for baud rate, parity, stop bits, and data bits

One micro-jumper for 100 ohm RS-422 termination

One micro-jumper for RS-422 or RS-485 operation

POWER: 125 mA @12 VDC

CONFIDENTIAL INFORMATION © 2003 AMX Corporation. All rights reserved. AMX and the AMX logo are all trademarks of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. AMX does not assume responsibility for any errors or omissions.

AXC-232++

RS-232/422/485 Interface Card (enhanced functionality)

FG725-10

Many audiovisual and computer-based devices can be remotely controlled using RS-232 or RS-422 commands. The AXC-232++ RS-232/422 Interface Card can generate virtually unlimited numbers of product/function commands as they are programmed into the AXC-EM Master Card. As needs and technology change, existing cards can be reprogrammed or new cards added, one for each device.

APPLICATION

Advanced RS-232/422/485 data control and receive

CONTROL PORT

RS-232/422/485 port (300-115,200 baud), XON/XOFF, CTS/RTS

INCLUDES

Onboard 32-bit processor and 384KB non-volatile memory

1,000 Byte serial input buffer; 1,000 Byte AXLink buffer

Two status LED indicators for transmit and receive

One setup switch for baud rate, parity, stop bits, and data bits

One micro-jumper for 100 ohm RS-422 termination

One micro jumper for RS-422 or RS-485 operation

POWER: 160 mA @ 12 VDC

DIMENSIONS (HXD): 2.7" x 12.8" (69.3 mm x 325.6 mm)

WEIGHT: 4.8 oz (136.1 g)

AXC-X10

X-10 Power Line Interface Card

FG747-K

The X-10 system is a unique way to control various devices in the home by sending the commands throughout the house via the built-in AC wiring. X-10 system modules can turn electric lights on and off, start and stop motors and pumps, open and close drapes, water the lawn, heat up the hot tub, and start the coffee maker. The AXC-X10 X-10 Power Line Interface Card, when used with the X-10 Power Line Interface Module, provides direct control of most X- 10 modules with all the programming features of the AMX Axcess system. The AXC-X10 can handle up to 256 devices on each system, using all 16 house and unit codes.

APPLICATION

Controls up to 256 devices that accept X-10 power line control commands

CONTROL PORT

X-10 control port

INCLUDES

Three status LEDs for online, transmit, and receive (future version)

X-10 Power Line Interface Module model #TW-523 with cab

For more information about AMX products and services visit www.amx.com