4.2 Mounting the IVS on the camera

The following tools are needed to mount the IVS:

The CCD optic module is mounted on the viewfinder of

– 1.2 x 8 mm screwdriver or coin.

the ARRIFLEX 535B, the inserter/antiflicker module is

If the beam splitter is to be changed:

placed on top of the electronic cover.

 

 

– Phillips screwdriver size 0

• Be sure to use a 80 : 20 beam splitter instead an 50 : 50

– Phillips screwdriver size 1

beam splitter. Change if necessary.

– 1.5 mm allen key

 

 

– Straight pair of tweezers.

Note:

Because of the high speed video optic (Academy

 

 

or Silent), it is no longer necessary to use a 50: 50

Disconnect camera from all power supplies.

 

beam splitter, as it was with other color video assists.

Do not use force

 

The IVS is designed to work with an 80 : 20

Ensure clean contacts.

 

beam splitter.

Support the viewfinder system.

Do not touch optical surfaces.

Setup

15