attachment screw § into the camera handle without closing it and push the inserter/antiflicker module as far to the right as possible. Close the attachment screw on the camera handle.

Secure the CCD optic module by closing the screw ring § clockwise.

4.2.3 Cabeling

Connect the RS-cable § between the inserter/anti- flicker module and the camera (RS-connectors). It is recommended to observe the color coding to ensure that the cable is as close to the camera as possible.

Connect the data cable ZV4 § between the camera (CCU-connector) and the IVS (data connector).

Without a data cable ZV4 Time-Code and Pull-Down information as well as data transfer to the IVS via the serial interface are not available.

Note:

If neither time code is used nor data is sent via

 

the serial interface, it is possible to work without

 

the data cable ZV4.

 

attachment screw

inserter/antiflicker module

screw ring

 

 

 

 

 

 

data cable ZV4

RS cable

 

 

 

Setup