13.3Creating new Iris Tables with the Iris Table Wizard

● Click on the headword „<new>“ in the User Iris List and click „Edit Iris Table“. This will start the Iris Table Wizard.

Lens Manager

Step 1

Enter the range of your iris

Some lenses may have a „CLOSE“ position where the iris is shut completely. If so, check „Yes“ in the box.

Enter open and close iris values of your lens.

Step 2

Mount Lens Motor and Calibrate

Attach a Controlled Lens Motor

(CLM-1/2) to the LDB or UMC.

Start calibration.

Note: Alternatively the buttons on WMU-2/3 or WHA-2/3 can be used.

Step 3

Toggle stop position

Depending on how the lens was mounted the iris may not be in the open position at this stage.

Click Toggle if the iris is not on the open position.