Calibrating Continuous Media

1Press the PRINT/PAUSE key until the printer display shows Pause on the display.

2Press PREV or NEXT key until the Calibrate menu is displayed.

Pause: Calibrate

Continuous *

3Press the + or - key until Continuous is displayed.

4Press the SELECT key. The printer will feed a short length of media and will then be calibrated for continuos media. The display will show the following prompt:

Pause: CONTINUOUS

Media Calibrated

5Press the PRINT/PAUSE key to return the printer to a Ready state.

Calibrating Inverted Gap Media

Some examples of inverted gap media include clear labels with an opaque liner, a material which has sensing marks on the label itself, or a material on which you must sense on a preprinted image.

When using media of this type, the printer is calibrated using the Gap Calibration method outlined previously in this chapter.

The only difference in the procedure is that you would align the sensing mark when the printer prompts for placement of the liner or gap.

QLS-4100 X

38