Table 1-1  Technical and Environmental Specifications (cont.)
| Electrical | ●  | |
| Requirements | ● Outlet must not be controlled by an on/off switch | |
| ● Grounding to comply with Underwriters Laboratories (UL) 1459: | ||
| 
 | ||
| 
 | A. An insulated grounding conductor that is not smaller in size and equivalent in insulation material and | |
| 
 | thickness to the grounded and ungrounded branch circuit supply conductors, except that it is green | |
| 
 | with or without one or more yellow stripes, is to be installed as part of the circuit that supplies the pro- | |
| 
 | duct or system. | |
| 
 | B. The grounding conductor mentioned in item A is to be connected to ground at the service equipment. | |
| 
 | C. The  | |
| 
 | type, and the grounding conductors serving these receptacles are to be connected to earth ground at | |
| 
 | the service equipment. | |
| 
 | 
 | |
| Wiring | ●  | |
| 
 | ● Other standard telecommunications equipment  | |
| 
 | machines, etc.):  | |
| 
 | ● Bridging adapter: AT&T 267F2 | |
| 
 | ● Range: 1,000 feet (305 meters) for MLS phones; 3,000 feet (915 meters) for standard dev- | |
| 
 | ices | 
Local Phone
Company
Information
●FCC registration number: AS5 
●REN outside line jack: 0.9A per line jack
●REN (PARTNER phone): 0 (zero)
●Jack type: RJ11C
●Loop start lines