Cooling and Airflow

ATTO Technology, Inc.

ATTO FibreBridge Installation & Operation Manual

Environmental

The FibreBridge 2200 is designed to operate in an environment that is 0°-40°C, 0-90% humidity and non- condensing.

Cooling and Airflow

There are two fans in the FibreBridge 2200R/D. Each can provide approximately 3 CFM of airflow. Cooling is from side to side where air enters in from the left side and is exhausted out the right. Ambient air near the inlets should not exceed 40°C.

WARNING: DO NOT BLOCK THE VENTS ON EITHER SIDE OF THE MAIN ENCLOSURE. DOING SO MAY CAUSE OVERHEATING AND COULD DAMAGE THE PRODUCT.

Figure 5.5 Cooling Airflow

Power Supply

The FibreBridge 2200R/D contains a universal supply that provides the necessary power for the bridge board and the cooling fans. Refer to the following specifications.

Input voltage: 110/230V AC, with an operating input range of 90-132V AC or 175-264V ac, 47- 63Hz, single phase. The AC input range selection is automatic. No manual jumper or switch over is required.

Output voltage: +12 Volts @ 5 Amps (60 watts) continuous, 5.8 amps (70 watts) peak.

Power Draw: The maximum power draw is 2 Amps @ 110 Volts.

IEC Power Receptacle and Switch

The supply has one standard IEC320 power receptacle and switch. This allows for easy adaptability to different voltage standards throughout the world.