ATTO Technology, Inc. | ATTO FibreBridge Installation & Operation Manual |
and the Report LUNs command as described in the next section. FibreBridge hierarchical addressing is limited to the
SCSI-3 REPORT LUNs Command
The
What to Expect When Setting Device IDs
Most users will be able to use the FibreBridge Default Addressing Method to achieve full functionality.
Setting the ID of the FibreBridge
The ID is determined from either the Soft or Hard Fibre Channel ID of the FibreBridge (AL_PA). The FibreBridge is set to use Soft IDs by default. The bridge can be set to use a Hard ID by using FibreBridge Services to set the appropriate bit in the NVRAM. The LUN of the FibreBridge can also be set using FibreBridge Services (BridgeTools is recommended). The default value is 14.
If you want the FibreBridge to be detected by the operating system, its Soft Fibre LUN value must be set within the range of the operating system. The bridge does not need to be detected for normal operation. The bridge DOES need to be detected if you want to use the
Addressing Connected SCSI Devices
Below is the default addressing mode bit definitions. Bits 0 through 7 are used to fully define a SCSI device with a Target ID and a LUN connected to one of the two FibreBridge busses.
Bit Number
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
0 | 0 |
|
| N/A |
|
|
| LUN |
|
| Target |
| Bus |
An operating system will identify this SCSI device under the
The four bit Target Field gets filled in from the SCSI ID (0 through 15) that you select for your connected SCSI device. The three bit LUN Field gets filled in from the SCSI LUN (0 through 7) selected for your connected SCSI device. Since the FibreBridge contains two independent busses, but is only being detected as a single device from the host's point of view, the FibreBridge must manage the addressing between bus 1 and bus 2. The bus bit(s) in the LUN byte is used to distinguish between SCSI bus 1 and
2.If you set the bus bit(s) to 0, SCSI Bus 1 of the FibreBridge will be selected. A 1 will select Bus 2. The default addressing mode of the FibreBridge has the Bus Identifier bit in position 0. This translates to Bus
ATTO Technology, Inc.
- 42 -