Field Description
For Outlets Entercd <PDU_ID >/outletsa nd enter s howto seelistof ou tletsand theactions that
canbe taken (commands that can be executed) for each outlet as shown below.
Name Eitherthe default XX-XX-XXPXX_n_nor an administrator-assigned name
Port PDUoutlet number
Type Outlet
Status ON/OFF
Action None
To viewi nformationabout the console serverand connected devices:1. Log into the CLI and enter cd access to ch ange to the Access level.
--:- / cli-> cd access
2. Enter show. Information about the console server and th e ports the current user isauthorized to access ap pears.
--:- access cli-> show
Name Port Type Status
=====================================
ACS6016-0011223344
21-67-72-p-1 1 serial in-use
21-67-72-p-2 2 serial idle
21-67-72-p-4 4 serial idle
myPDU 3|1 PM8|15A 8|8
Type ls to see available sub-nodes
--:- access cli->ls
ACS6016-0011223344/
21-67-72-p-1/
21-67-72-p-2/
21-67-72-p-4/
myPDU/
Type show to see the content of the page
--:- access cli->
Chapter 3: Port Access a nd Configuration Examples 23