2. Enter show to view th e configuration o f port 3.
--:- serial_ports/physical cli-> show
Selected items: 3
Port: 3
enable_cisco_rj45_pin-out = no
status = enabled
speed = 9600
parity = none
data_bits = 8
stop_bits = 1
flow_control = none
Type ls to see available sub-nodes
--:- serial_ports/physical cli->
3. Enter set status=enabled then enter save to set th e Serial_Profile to Power, enable theport and commit the changes.4. Enter show to verify the configuratio n.
--:- serial_ports cli-> show
Port Device Name Profile Settings
==== ====== ================== ======= =========================
1 ttys1 ACS6016-0088664422 cas 9600_8N1_telnet-ssh_local
2 ttys2 21-67-72-p-2 cas 9600_8N1_telnet-ssh_local
3 ttys3 power cas 9600_8N1_telnet-ssh_local
4 ttys4 21-67-72-p-4 cas 9600_8N1_telnet-ssh_local
5 ttys5 21-67-72-p-5 cas 9600_8N1_telnet-ssh_local
6 ttys6 21-67-72-p-6 cas 9600_8N1_telnet-ssh_local
7 ttys7 21-67-72-p-7 cas 9600_8N1_telnet-ssh_local
8 ttys8 21-67-72-p-8 cas 9600_8N1_telnet-ssh_local
9 ttys9 21-67-72-p-9 cas 9600_8N1_telnet-ssh_local
10 ttys10 21-67-72-p-10 cas 9600_8N1_telnet-ssh_local
11 ttys11 21-67-72-p-11 cas 9600_8N1_telnet-ssh_local
12 ttys12 21-67-72-p-12 cas 9600_8N1_telnet-ssh_local
13 ttys13 21-67-72-p-13 cas 9600_8N1_telnet-ssh_local
14 ttys14 21-67-72-p-14 cas 9600_8N1_telnet-ssh_local
15 ttys15 21-67-72-p-15 cas 9600_8N1_telnet-ssh_local
16 ttys16 dial-in 38400
Chapter 3: Port Access a nd Configuration Examples 27