To setup a console accessservice (CAS) port:
1. Log onto th e CLI as an administrator.
--:- / cli->
2. Enter set_cas ports/serial_ports/ fol lowed by a space and the nu mbero fth e port you
want to configu re(po rt 1 is used as an example).
--:- / cli-> set_cas ports/serial_ports/ 1
3. Enter show to view th e status of port 1.
Selected items: 1
Port: 1
enable_cisco_rj45_pin-out = no
status = enabled
speed = 9600
parity = none
data_bits = 8
stop_bits = 1
flow_control = none
Type ls to see available sub-nodes.
--:#- [serial_ports/physical] cli->ls
cas/
data_buffering/
alerts/
power/
Type show to see the content of the page.
--:#- [serial_ports/physical] cli->
4. Enter set status=enabled, then en ter show and save as shown to en able the configured
port and verify and save the configuration .
--:- serial_ports/physical cli-> setstatus=enabled
--:- serial_ports/physical cli-> show
--:- serial_ports/physical cli-> save
To enablea power management port:
1. Log onto th e CLI as an administrator an d enter set_power ports/serial_ports/ < port
number> to select a port with a PDU co nnected (port 3 is used as an example).
--:- / cli-> set_power ports/serial_ports/ 3
26 Cyclades™ ACS6000 A dvanced Console Server Command Reference Guide