Controlling
switch value
11
22
34
48
516
632
764
8128
Example : address 83
DIP switch | 1 2 3 4 5 6 7 8 |
setting | 1 1 0 0 1 0 1 0 |
Summary : 1x1 + 1x2 + 0x4+ 0x8+ 1x16 + 0x32 + 1x64 + 0x128 = 83
b. How to control the projector or projectors.
The projector's address may be set to any value between 0 and 255. When the address is set, the projector can be controlled now :
-RCU for addresses between 0 and 9.
-computer, e.g. IBM PC (or compatible), Apple MAC, etc. for addresses between 0 and 255.
Note : A projector will respond to a RCU set to an address of '0' regardless of what address is set in the projector itself.
c. Using the RCU.
Before using the RCU, its is necessary to enter the projector address into the RCU (only when that address is between 1 and 9). The projector with the corresponding address will listen to that specific RCU.
When address 0, 'zero address' is programmed into the RCU, every projector, without exception will listen to the commands given by this RCU.
How to display a projector address?
Press the ADDRESS key (recessed key on the RCU) with a pencil. The projector's address will be displayed in a 'Text box'. This text box disappears after a few seconds. To continue using the RCU, it is necessary to enter the same address with the digit buttons (address between 0 and 9). For example : if the Address key displays projector address 003, then press "3" digit button on the RCU to set the RCU's address to match the projector's address. Do not press digit 003. This will address the remote to '0' and control all projectors in the room.
How to program an address into the RCU?
Press the ADDRESS key (recessed key on the RCU) with a pencil and enter the address with the digit buttons. That address can be any digit between 0 and 9.
When programming '0', zero address, the RCU will control any projector regardless of the projector's address. This feature allows multiple projectors with different addresses to be controlled by a single RCU.
Picture controls with direct access.
When an image control is pressed, a text box with a bar scale, icon and function name of the control, e.g. 'brightness...' appears on the screen (only if text is ON). See example screen. The length of the bar scale and the value of the numeric indication indicate the current memorized setting for this source. The bar scale changes as the + or - buttons of the control on the RCU are pressed or the + or - buttons on the local keypad.
PROJECTOR ADDRESS |
001 |
| BRIGHTNESS |
0 | 63 |
| 5975348 BARCOVISION 8200 280497 | |
|