DS72 Host Module

from a DB-25 connector to an RJ-45 connector is also available from Bay Tech, upon request (Bay Tech Part No. 25FRJ45PC-4). The 8-pin crossed modular cable is configured for these adapters.

NOTE: Use rollover (RJ08X007) RJ-45 cables when using modular connectors to interface the DS-Series to another BayTech product with modular connectors, such as the RPC Remote Power Control Unit.

10/100 BASE-T NETWORK PORT CONNECTION

Using a straight 10/100 Base-T cable, connect the RJ-45 port labeled ETHERNET on the HOST module to an RJ-45 port on the network hub. The LINK (link integrity) LED, located on the front panel of the HOST, illuminates when a good connection is established between the HOST and the hub.

EXTERNAL MODEM CONNECTION

Using the 25MRJ45MD-6 adapter (or other applicable adapter) and the RJ08X007 crossed cable, connect the COM (or serial) port of the modem to the RJ-45 port labeled EIA-232 on the DS62-MD4 module. Using an RJ04X007 (RJ-11) modular cable, connect the port labeled “LINE” on the modem to the Telco wall jack. Using communications software package, dial the modem. Setup Instruction at end of manual.

Installation

UNPACKING

Compare the unit and serial number of the equipment you received to the packing slip located on the outside of the box. Inspect equipment carefully for damage that may have occurred in shipment. If there is damage to the equipment or if materials are missing, contact BayTech technical support at 228- 563-7334or call toll free inside the United States at 800-523-2702. At a minimum, you should receive the following:

1.The DS72 Module.

2.Manual insert describing the location of the User’s Guide on BayTech’s website at www.baytech.net.

3.Power Cords that may be attached to the unit (if order requested detachable cords).

4.1 ea. DE-9 (9 pin) PC com port adapter -- 9FRJ45PC (with Cisco Interface) or 9FRJ45PC-1.

5.1 ea. RJ-45 Roll over cable -- RJ08X007.

NOTE: Keep shipping container and packing material in the event future shipment is required.

PREPARING THE INSTALLATION

The installation area should be clean and free of extreme temperatures and humidity. Allow sufficient space behind the DS unit for cabling and receptacle connections. Access to installation site should be restricted to authorized personnel. Installation of these units should be limited to ITE and Telco server environments.

Power

CAUTION: This unit is intended for indoor use only in a clean and free of extreme temperatures and humidity. Do not install near water or expose this unit to moisture. To prevent heat buildup, do not coil the power cord when in use. Do not use extension cords. Do not attempt to make any internal changes