Power control port

The Wizard IP Plus provides a serial port for connection to one or more optional power control units. This allows you to control the mains power being supplied to the connected host(s) so that an authorised remote user can, if necessary, perform a complete cold reboot on a failed host system.

The control connector of the first power switch is connected, via serial cable, to the rear panel of the Wizard IP Plus. Any additional power switches are then connected via a ‘daisy-chain’ arrangement to the first power switch. Each power switch box is then given a unique address and access to each power port (8 ports on each power switch box) is gained using a combination of the switch box address and the port number.

‘Daisy-chain’

control

BLACK BOX

 

Power

connections

724-746-5500

 

 

 

LOC REM VNC 100 LNK PWR

switch

 

 

 

 

 

 

boxes

Box 1

IN

1

2

3

4

5

6

7

8

 

OUT

 

 

 

 

 

 

 

 

Box 2

IN

1

2

3

4

5

6

7

8

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power to computer

 

 

 

 

 

 

 

 

 

Box 2, port 6 - address: 26

Box 3

IN

1

2

3

4

5

6

7

8

 

OUT

 

 

 

 

 

 

 

 

Box 4

IN

1

2

3

4

5

6

7

8

The power ports are connected to the power inputs of each computer and the power switch box(es) are then connected to a mains power supply.

IMPORTANT: Power switching devices have a maximum current rating. It is essential to ensure that the total current drawn by the equipment connected to the power switching device does not exceed the current rating of the power switching device. You must also ensure that the current drawn from any mains socket does not exceed the current rating of the mains socket.

Setting up, configuring and using power switching requires three main steps:

Connect and address the switch boxes

Configure the power strings

Operate remote power switching

To connect and address the switch boxes

Note: The Wizard IP Plus can be powered on during this procedure, however, the switch boxes should be switched off.

1Mount up to four switch boxes in positions where they are close to the computers that they will control and not too distant from the Wizard IP Plus (preferably within 2.5 metres).

2Use a serial cable with an RJ9 and a 9-pin D-type connector (see Appendix 7 for specification). Connect the RJ9 plug to the socket marked ‘IN’ on the first switch box. Connect the other end to the socket marked ‘POWER CONTROL’ on the Wizard IP Plus.

SOLE

VG

A

 

DVI

 

PO

 

 

 

 

 

VG

WER

CONT

 

 

 

 

 

 

 

 

R

 

 

 

OL

 

 

K/

 

 

 

SWITCH

 

 

 

M

 

 

 

 

V

 

 

 

M

3For each of the remaining switch boxes (if used), use a serial cable with RJ9 connectors at both ends (see Appendix 7 for specification). Connect one end to the socket marked ‘OUT’ of the previous box and the other end to the socket marked ‘IN’ of the next box.

4Set the addressing switches on each switch

box using the two micro switches marked Box Switch 1 Switch 2

‘Slct’ on the front panel. The box connected

1

Off

Off

directly to the Wizard IP Plus is Box 1 and

2

On

Off

so on, down the daisy-chain line to Box 4 at

3

Off

On

the end.

4

On

On

5 Connect IEC to IEC power leads between

Off = switch upwards

 

each port and the power input socket

 

On = switch downwards

 

of each computer that requires power

Switch 1 is on the left side

 

switching. Carefully note to which power

ports, on which boxes, each computer is connected. If server systems have multiple power inputs, then each input must be connected via separate ports, which can be on the same, or different boxes.

6 Connect each box to a suitable mains power input.

Now proceed to the configuration stage covered in the Power switching configuration section within the Configuration chapter.

®

   



14