26.

Attaching the Smart Guard

System

To prevent personal injury, always disconnect
plug from power source before attaching or
removing the Smart Guard System.
POSITIONING THE RIVING KNIFE
1.Remove table insert using finger hole.
2.Raise the blade as high as it will go and set it perpendicular to
table (0° on bevel scale) (Fig. 5).
3.Rotate the riving knife release lever 1clockwise, so that it
points upward (Fig. 5).
4.Pull riving knife 2towards release lever to disengage it from
the pins 3.
5.Slide the riving knife 2up to its highest position, so that it is
directly over the center of the blade (Fig. 6).
6.Align holes in riving knife with pins 3and lock the release lever
1by rotating it counterclockwise. Push/pull riving knife to verify
that it is locked in place (Fig. 6).
7. Replace table insert (Fig. 7).
continued on page 28
Assembly
FIG. 5
FIG. 6
1
2
1
3
2
WARNING
!