DCN Wireless Installation and User Instructions System Design and Planning
en 19
2.8Examples
2.8.1Cable lengths
Legend |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
R | Regenerative |
|
|
|
|
|
| RS 232 | Port 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Mains |
| ||
P | Power overload |
|
|
|
|
|
| RS 232 | Port 2 | Audio In 1 | Audio Out 1 | Audio In 2 | Audio Out 2 |
|
|
Network | 1 | 2 | Trunk | 1 | 2 | Fault |
|
|
|
| 230 |
|
| ||
|
|
|
|
|
|
|
| NC C C NO |
|
|
|
|
|
| |
|
| 48V | 48V |
|
|
|
|
|
|
|
| 115: | T2.5A 250V | ||
|
|
|
|
|
|
|
|
|
| 230: | T2A H 250V | ||||
|
|
|
|
|
|
|
|
|
|
|
| 2 m | |||
|
|
|
|
|
|
|
| Trunk |
|
|
|
|
|
| |
|
|
|
|
|
|
| In | Out |
| Out | Out |
|
|
|
|
|
|
|
|
|
|
|
|
| Trunk |
|
|
|
|
| |
| LBB4114/00 |
|
| LBB4114/00 |
|
|
|
|
|
|
|
| 100 m | ||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| 100 m |
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
|
|
|
| R |
|
|
|
|
|
|
|
|
|
| LBB4114/00 |
|
|
|
|
|
|
|
| LBB4114/00 |
|
| 100 m | ||
|
| 100 m |
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
|
|
|
| R |
|
|
|
|
| 240 m |
|
|
|
|
|
|
|
|
|
|
|
| 240 m |
| LBB4114/00 |
|
|
|
|
|
|
| LBB4114/00 |
|
|
|
| ||
| P |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 250 m (max) |
|
|
|
|
|
|
|
|
|
|
|
| 250 m (max) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| P |
|
|
|
|
|
|
| |
|
| 2 m |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 x 2 m = 10 m |
|
| 5 x 2 m = 10 m |
|
|
|
|
|
|
|
|
|
|
|
|
|
figure 2.4: Example with cable lengths
Point I
The maximum available power with 240 m of extension cables is 19 W (refer to figure 2.3). Because the first and second trunk splitter use 2.6 W, the available power at point I is 19 - 2.6 = 16.4 W.
Point II
The maximum available power with 240 m of extension cable is 25 W (refer to figure 2.3). Because the first and second trunk splitter use 2.6 W, the available power at point II is 25 - 2.6 = 22.4 W.