DCN Wireless Installation and User Instructions System Design and Planning

9.6Miscellaneous

table 9.7: Miscellaneous

Basic standard ESD:

According EN 61000-4-2.

Contact discharge: 4 kV and air discharge: 8 kV

Basic standard mains harmonics and voltage fluctuations, flicker: According EN 61000-3-2 and EN 61000-3-3

Basic standard RF electromagnetic fields:

According EN 61000-4-3

RF conducted: 150 kHz - 80 MHz: 3 Vrms

RF radiated 80 - 1000 MHz: 3 V/m

Cellular telephone (GSM) dummy test: at 20 cm speech distance

Criteria: not effecting normal operation. Magnetic immunity:

Rack mounting: 50 Hz - 10 kHz: 4 - 0.4 A/m

No rack mounting: 50 Hz - 10 kHz: 3 - 0.03 A/m

Basic standard low energy electrical fast transients, bursts: According EN 61000-4-4

Mains: fast transients: 1 kV; signal and control data lines: 0.5 kV Basic standard high energy surges:

According EN 61000-4-5

Mains: surges: 1 kV CM and 0.5 kV DM.

Basic standard voltage dips, short interruptions, variations: According EN 61000-4-11

Mains: voltage dips 100% for 1 period, 60% for 5 periods, > 95% for 5 seconds.

en 35

Bosch Security Systems 2007-02 9922 141 70691 en

Page 35
Image 35
Bosch Appliances 9922 141 70691 en manual Miscellaneous