DCN Wireless Installation and User Instructions Central Devices

en 39

10.2.2 Rear view

The rear of the central control unit (refer to figure 10.1) contains:

5RS232 ports - Connects a PC, remote controllers or video cameras to the central control unit (refer to 10.5.8).

6 Power inlet - Connects the central control unit to the mains power supply with a power cable (refer to 10.5.1).

7 Ground screw - Connects the central control unit to ground.

8Optical network sockets - Connects the central control unit to the optical network (refer to 10.5.3).

9DCN sockets - Connect the central control unit to the DCN (refer to 10.5.2).

10Fault contact - Connects the central control unit to devices to sense the condition of the central control unit (refer to 10.5.7).

11Audio inputs - Connect the central control unit to external analog audio sources (refer to 10.5.5).

12Audio outputs - Connect the central control unit to external analog audio devices (refer to 10.5.6).

13Voltage selector - Selects the voltage on which the central control unit must operate (refer to 10.5.1).

14Fuse holder - Prevents damage to the internal power supply unit of the central control unit (refer to 10.5.1).

10.3Internal settings

10.3.1 Overview

Warning

Before you open the central control unit, discon- nect it from the mains power supply. Electrical discharges from the mains power supply can kill you.

Caution

Before you open the central control unit, take measures to prevent electro-static discharges.

The PCBs of the central control unit (refer to figure

10.2) contain:

15Software LEDs - Show the condition of the software of the central control unit. When the software runs correctly, the yellow and green LEDs flash.

16S600 switches - Reserved (refer to 10.3.2).

17X605 jumper block - Enables or disables the watchdog (refer to 10.3.5).

18Reset switch - Starts the central control unit again.

19Optical network processor indicator - Comes on when the optical network processor operates correctly.

20S500 switches - Configure the RS232 ports of the central control unit (refer to 10.3.3).

21X600 jumper block - Connects and disconnects the internal back-up battery of the central control unit (refer to 10.3.4).

22X104 jumper block - Connects and disconnects the mechanical ground and the electrical ground (refer to 10.3.6).

23Fuse - Prevents damage to the electronic components in the central control unit.

Bosch Security Systems 2007-02 9922 141 70691 en

Page 39
Image 39
Bosch Appliances 9922 141 70691 en manual Internal settings, Rear view