10.3.4 Internal back-up battery

Use the X600 jumper block to connect and disconnect the internal back-up battery of the central control unit (refer to table 10.4).

Note

When your central control unit is new, you must energize the central control unit to charge the internal back-up battery. The internal back-up battery is fully charged after 24 hours.

10.3.5 Watchdog

Use the X605 jumper to enable or disable the watchdog of the central control unit (refer to table 10.5).

table 10.5: X605 jumper block (* = default)

Jumper shunt

Description

Present

The watchdog is disabled. The

 

central control unit does not

 

start again after an error.

Not present*

Enables the watchdog. The

 

central control unit starts again

 

after an error.

table 10.4: X600 jumper block (* = default)

Jumper shunt

Description

1 and 2 *

Connects the internal back-up

 

battery. When you stop the

 

central control unit, the memory

 

of the central control unit is not

 

erased.

 

 

2 and 3

Disconnects the internal

 

back-up battery. When you stop

 

the central control unit, the

 

memory of the central control

 

unit is immediately erased. The

 

memory of the central control

 

unit contains:

 

• The license code

 

• The settings of the

 

interpreter desks.

Note

You only have a license code when you use the system in combination with:

The PC Control Software

A remote controller

Note

The subscription list is not erased when the internal back-up battery is empty. The subscription list is stored in another location.

Note

When you disable the watchdog, the system can operate incorrectly.

10.3.6 Ground

Use the X104 jumper block to connect and disconnect the system ground and the ground of the central control unit (refer to table 10.6). For example, you can connect the system ground and the ground of the central control unit to prevent hum.

table 10.6: X104 jumper block (* = default)

Jumper shunt

Description

1 and 2

Connects the system ground

 

and the ground of the central

 

control unit.

2 and 3 *

Disconnects the system ground

 

and the ground of the central

 

control unit.

Note

When you connect the system ground to the ground of more than one device in the system, you can create ground loops. Ground loops can cause hum.