DCN Wireless Installation and User Instructions Central Devices
en 42
10.3.4 Internal back-up battery
Use the X600 jumper block to connect and disconnect the internal
Note
When your central control unit is new, you must energize the central control unit to charge the internal
10.3.5 Watchdog
Use the X605 jumper to enable or disable the watchdog of the central control unit (refer to table 10.5).
table 10.5: X605 jumper block (* = default)
Jumper shunt | Description |
Present | The watchdog is disabled. The |
| central control unit does not |
| start again after an error. |
Not present* | Enables the watchdog. The |
| central control unit starts again |
| after an error. |
table 10.4: X600 jumper block (* = default)
Jumper shunt | Description |
1 and 2 * | Connects the internal |
| battery. When you stop the |
| central control unit, the memory |
| of the central control unit is not |
| erased. |
|
|
2 and 3 | Disconnects the internal |
| |
| the central control unit, the |
| memory of the central control |
| unit is immediately erased. The |
| memory of the central control |
| unit contains: |
| • The license code |
| • The settings of the |
| interpreter desks. |
Note
You only have a license code when you use the system in combination with:
•The PC Control Software
•A remote controller
Note
The subscription list is not erased when the internal
Note
When you disable the watchdog, the system can operate incorrectly.
10.3.6 Ground
Use the X104 jumper block to connect and disconnect the system ground and the ground of the central control unit (refer to table 10.6). For example, you can connect the system ground and the ground of the central control unit to prevent hum.
table 10.6: X104 jumper block (* = default)
Jumper shunt | Description |
1 and 2 | Connects the system ground |
| and the ground of the central |
| control unit. |
2 and 3 * | Disconnects the system ground |
| and the ground of the central |
| control unit. |
Note
When you connect the system ground to the ground of more than one device in the system, you can create ground loops. Ground loops can cause hum.
Bosch Security Systems