10.6.3 Main

When you start the central control unit, the display first shows Starting. The display then shows the Main menu item:

The Main menu item contains:

An indicator that shows the volume level of the loudspeakers of the contribution devices. Turn the knob to change the volume level (refer to 12.6).

The name of the central control unit. The default name is CCU. You can change the name with the 4L Unit Name menu item (refer to 10.6.8).

The microphone mode and the maximum number of activated microphones. You can change the microphone mode and the maximum number of activated microphones with the 4C Mic. Mode menu item (refer to 10.6.8).

Note

When a PC is connected to the central control unit, the Main menu item also shows PC.

Note

When the condition of the central control unit changes, the Main menu item shows a message (refer to table 10.21). Such a message goes out of view when you push the knob.

Note

If you do not turn or push the knob for three minutes, the display automatically goes back to the Main menu item. The display does not automatically go back to the Main menu item from these menu items and their sub-menus:

2A Source/Volume

4Ia Assign Operator

4Ib Assign Chairman

10.6.4 Fault status

Use the 1 Fault Status menu item to see the condition messages of the central control unit. If there is more than one message, the display shows the most important message (refer to table 10.21).

table 10.21: Messages (low to high importance)

Messages

Description

No Fault

The central control unit

 

operates correctly.

Low Battery

The battery pack of a

 

wireless device is

 

empty within 1 hour.

Bad Signal

A wireless device has a

 

bad signal reception.

Incompatible SW

The wireless access

 

point has a

 

incompatible software

 

version.

Invalid Software

The central control unit

 

cannot start. The

 

central control unit

 

does not contain the

 

correct software.

Downloading

The central control unit

 

downloads software.

Bosch Security Systems 2007-02 9922 141 70691 en