10.5.8 RS232 ports

You can connect a PC, remote controllers or video cameras to the RS232 ports of the central control unit (refer to the DCN Next Generation Installation and User Instructions). The central control unit has 2 RS232 ports (refer to figure 10.11). You can set the protocol and the baudrate of the RS232 ports with the S500 switches (refer to 10.3.3).

5 1

9 6

figure 10.11: RS232 port, connection

table 10.18: RS232 port, connection

Pin

Definition

Description

1

DCD

Data Carrier Select

2

RxD

Receive Data

3

TxD

Transmit Data

4

DTR

Data Terminal Ready

5

SG

Signal Ground

6

DSR

Data Set Ready

7

RTS

Request To Send

8

CTS

Clear To Send

9

RI

Ring Indicator

table 10.19: RS232 ports

Number of connections:

2x 9-pole SUB-D socket Location:

Rear side

Maximum cable length:

9600 baud: 15 m, >9600 baud: 3 m Signal levels:

EIA RS232-C interface specifications