DCN Wireless Installation and User Instructions Central Devices

en 41

10.3.2

S600 switches

 

table 10.1: S600 switches (* = default)

Switch

Position

Description

S600-1

ON*

Reserved. Do not change the position of this switch.

 

OFF

 

S600-2

ON

Reserved. Do not change the position of this switch.

 

OFF*

 

S600-3

ON

Reserved. Do not change the position of this switch.

 

OFF*

 

S600-4

ON

Reserved. Do not change the position of this switch.

 

OFF*

 

S600-5

ON

Reserved. Do not change the position of this switch.

 

OFF*

 

 

 

 

S600-6

ON

Reserved. Do not change the position of this switch.

 

OFF*

 

S600-7

ON

Reserved. Do not change the position of this switch.

 

OFF*

 

S600-8

ON

Enables the download of new firmware.

 

OFF*

Normal operation.

10.3.3 RS232 configuration

Use the S500 switches to configure the RS232 ports of the central control unit (refer to table 10.2 and table 10.3).

table 10.2: RS232 protocol (* = default)

Protocol

Port 1

 

Port 2

 

 

S500-1

S500-2

S500-5

S500-6

Open interface

Off

Off

Off

Off

Terminal

Off

On

Off

On

 

 

 

 

 

Full

On*

Off*

On

Off

Camera control

On

On

On*

On*

table 10.3: RS232 baudrate (* = default)

 

 

 

Baudrate

Port 1

 

Port 2

 

 

S500-3

S500-4

S500-7

S500-8

9.6k

Off

Off

Off

Off

19.2k

Off

On

Off*

On*

57.6k

On

Off

On

Off

115.2k

On*

On*

On

On

Bosch Security Systems 2007-02 9922 141 70691 en

Page 41
Image 41
Bosch Appliances 9922 141 70691 en manual 10.3.3 RS232 configuration