DCN Wireless Installation and User Instructions Central Devices

en 44

4 Connect the power cable to a power supply.

Warning

Make sure that the mains power supply is grounded. Electrical discharges from the mains power supply can kill you.

10.5.2 DCN

Connect the trunk of the DCN to the DCN sockets of the central control unit (refer to figure 10.5).

LED

figure 10.5: DCN

Each DCN socket has a red LED that comes on if there is an overload (refer to figure 10.5 and 3.5.4).

table 10.10: DCN connection

Number of connections:

2x DCN socket

Location:

Rear side

Power supply:

max. 65 W (refer to figure 2.1)

10.5.3 Optical network

Connect the trunk of the optical network to the optical network sockets of the central control unit with optical network cables (refer to figure 10.6).

LED

figure 10.6: Optical network

Each optical network socket has a red LED that comes on if there is an overload (refer to figure 10.6 and 3.5.4).

table 10.11: Optical network connections

Number of connections: 2x proprietary sockets

Location:

Rear side

Nodes:

2

Power supply:

max. 65 W (refer to figure 3.1)