D9412GV3/D7412GV3 Program Entry Guide 2.0 Panel and Area Wide Parameters

EN 14

2.2Phone Parameters

The program items in this category describe panel- wide characteristics for telephone dialing, receiver format, and supervision.

Phone # Format

Default:

Modem IIIa2

Selection:

Modem IIIa2 or Contact ID

Modem IIIa2

Modem IIIa2 Communication Format

Contact ID

ANSI-SIA Contact ID

 

 

Central Station Receiver Format for Transmission of Reports: Modem format provides many reporting advantages over the Contact ID format. Refer to the D6500 Report Directory (P/N: 74-04651-001) for more information about the effect of reporting formats.

Reports identify points as 001 through 247 and passcode User ID codes as 000 through 249 at the D6500 or D6600 Receiver (unless Point/User Flag is programmed Yes; refer to the Point/User Flag prompt in this section). When reporting point events, Modem IIIa2 Communication Format also sends point text to the D6500 or D6600 as programmed in Point Assignments.

Keypad Programming of Phone # Format

D1255

1.Refer to Figure 1 on page 7 to access Keypad Programming and navigate to the PHONE PARAMETERS option.

2.At the PHONE 1 - 4 prompt, enter the phone route number you wish to configure and press [ENT].

3.Press [NEXT] or [PREV] to toggle between Contact ID and ModemIIIa2 and press [ENT] to select the desired phone format.

When the keypad reads PARAMETER SAVED, your selection has been configured.

D1260

1.Refer to Figure 2 on page 8 to access Keypad Programming and navigate to the Phone Parameters option and press the corresponding softkey.

2.At the Phone (1-4)prompt, enter the phone route number you wish to configure and press [ENTER]. The current configuration shows.

3.Press the Edit softkey to change the phone format.

4.Select the softkey for the option to which you wish to change. Press the Save softkey

When the keypad reads Parameter Saved, your selection has been configured.

Point/User Flag

Default:

Yes

Selection:

Yes or No

Yes

The control panel sends a flag with

 

each report telling the D6500 or

 

D6600 to convert point numbers and

 

User ID numbers to COMEX format.

 

Refer to Table 5 and Table 6 for

 

conversion information. When this

 

parameter is programmed Yes,

 

points and User ID numbers are

 

converted, regardless of the

 

programming of the D6500 or D6600

 

Receiver for output to the computer

 

system. Refer to Appendix C in the

 

Conettix D6600/D6100

 

Receiver/Gateway Computer

 

Interface Manual (P/N: 4998122703).

 

 

No

The control panel does not send the

 

flag. The D6500 or D6600 outputs

 

point numbers as 001 to 247 (rather

 

than 100 to 732) and User ID

 

numbers as 000 to 249 (rather than

 

000 to F08), as indicated in Table 5

 

and Table 6.

 

 

This program item determines how point and User ID numbers are presented at the D6500 or D6600 display, printer, and computer RS-232 output.

When Phone # Format is Yes, the control panel sends expanded Bosch Modem IIIa2 Communication Format reports to the D6500 or D6600. If your central station data files are not set up for point and User ID number reporting, you can use this program item to convert these numbers to COMEX Reports.

When Phone # Format is Yes, the control panel sends expanded Bosch Modem IIIa2 Communication Format Reports to the receiver. Point/User Flag affects Bosch Modem IIIa2 Communication Format data as shown in Table 5. The Bosch Security Systems, Inc. D6500 or D6600 Receiver adds the leading zero in the User ID number with Point/User Flag programmed No.