Bosch Appliances D9412GV3 manual ## Disarm Level, ## Function Level

Models: D9412GV3

1 154
Download 154 pages 49.97 Kb
Page 76
Image 76

D9412GV3/D7412GV3 Program Entry Guide 2.0 Panel and Area Wide Parameters

EN 76

L## Disarm Level

Default:

Refer to the program record sheet

Selection:

I, D, or -

I

Users change the Master Armed

 

state and Perimeter Armed state to

 

Perimeter Instant. The armed state

 

does not change in other areas, and

 

the armed state does not change if

 

the area is already in the perimeter

 

instant or disarmed state. User

 

needs access level for Master

 

Armed (M) state.

 

 

D

Users change the local area’s

 

Master Armed state and Perimeter

 

Armed state to the Disarm state.

 

User needs access level for Master

 

Armed (M) or Perimeter Armed (P)

 

state. All areas within the scope of

 

the keypad assigned to the D# CC#

 

Scope in the access handler, and

 

areas to which the user has disarm

 

rights, disarm as programmed.

 

 

-

Users do not have disarm rights in

 

this area.

 

 

Burglar bells are silenced in the local area when a user disarms with a token or card or presents the token or card during an alarm. The user must use a passcode to silence a Fire Bell. Cancel Reports are sent after a valid passcode or token or card silences the bell.

Opening and Closing Reports are sent to the central station receiver if programmed.

For more information on programming this prompt for a shared area, refer to Access Control Readers Assigned to the Shared Area in Section 2.8.2 Shared- Area Characteristics on page 41.

L## Function Level

Default:

Refer to the program record sheet

Selection:

M, D, C, or -

 

 

MActivate the custom function assigned to the door in this area while the area is Master Armed or Disarmed only.

DActivate the custom function assigned to the door in this area while the area is Disarmed only.

CUser can activate the custom function assigned to the door in this area while the area is Master Armed, Perimeter Armed or Disarmed.

-User cannot activate the custom function assigned to the door in this area.

When a token or card can also disarm an area, the custom function starts after the area disarms.

A user does not require L## Security Level or L## Disarm Level authority to activate a custom function with a token or card.

Tokens or cards that are used to execute Custom Functions must have a passcode assigned to the corresponding User###.

Bosch Security Systems, Inc. 10/11 F01U170807-02

Page 76
Image 76
Bosch Appliances D9412GV3 ## Disarm Level, ## Function Level, Default Refer to the program record sheet Selection C, or