D9412GV3/D7412GV3 Program Entry Guide 2.0 Panel and Area Wide Parameters

EN 46

A# Fail to Close

Default:

No

Selection:

Yes or No

Yes

Fail to Close Report is sent for this

 

area if the area is not armed when

 

the Closing Window stop time occurs.

 

Note:

 

Program an exit delay time in

 

Exit Dly Time.

 

 

No

Fail to Close Report is not sent for

 

this area.

 

 If Auto Close is programmed

 

Yes, a Fail to Close Report is

 

sent because it occurs when the

 

Closing Window stop time

 

occurred.

 

 If Disable O/C in Window is

 

Yes, the Fail to Close Report is

 

followed by Closing Late or

 

Force) Close Late.

This item determines if a Fail to Close Report is sent for this area. Use to determine if a user failed to arm the area before the Closing Window expires. Normal Opening and Closing Reports do not need to be programmed to use this feature.

A# Restrictd O/C

Default:

 

No

Selection:

 

Yes or No

Yes

 

Restrict Opening and Closing

 

 

Reports for this area. A# Area O/C

 

 

must be programmed Yes to

 

 

generate Restricted Opening and

 

 

Closing Reports.

 

 

Note:

 

 

If a passcode is not required for

 

 

arming or disarming and this item

 

 

is Yes, the area sends only

 

 

Restricted Opening and Closing

 

 

Reports. In this case, Restricted

 

 

Reports are sent without User ID.

 

 

Opening/Closing Window does not

 

 

affect this report. Windows do not

 

 

prevent sending Restricted Opening

 

 

and Closing Reports from being sent.

 

 

Early or late designations are not

 

 

added to Opening or Closing Reports

 

 

when they are sent according to the

 

 

rules for Restricted Opening or

 

 

Closing Reports.

No

 

Do not Restrict Opening and Closing

 

 

Reports for this area.

 

 

Regardless of programming in

 

 

Authority Levels L## Restricted O/C,

 

 

reports are not restricted in this area

 

 

when this item is programmed as No.

 

 

Note:

 

 

Was Force Armed and Forced

 

 

Close Events can still be sent to

 

 

the central station if enabled in

 

 

Routing when force arming the

 

 

system.

 

 

 

This item determines if this area can restrict Opening and Closing Report activity.

A Restricted Opening Report refers to the control panel sending an Area Opening Report only when the area is disarmed after a non-fire alarm.

A Restricted Closing Report refers to the control panel sending a Force Closed Report only when the area was master armed with Controlled points that were faulted during the arming sequence. The sequence of reports generated by a restricted closing is: Was Force Armed, Forced Point, and Force Closed.

Bosch Security Systems, Inc. 10/11 F01U170807-02

Page 46
Image 46
Bosch Appliances D9412GV3 manual # Fail to Close, # Restrictd O/C, Exit Dly Time,  If Disable O/C in Window is

D9412GV3 specifications

The Bosch Appliances D9412GV3 is a perfect blend of functionality and innovation, designed to meet the needs of modern households. This dishwasher is part of Bosch's reputation for creating high-quality, energy-efficient home appliances. With a sleek design and advanced technology, the D9412GV3 stands out in the crowded market of dishwashers.

One of the main features of the D9412GV3 is its remarkable efficiency. With an Energy Star rating, this model is designed to minimize water and energy consumption while still delivering exceptional cleaning performance. The EcoSense technology optimizes water usage, ensuring every wash cycle is both effective and economical, making it a responsible choice for energy-conscious consumers.

The dishwasher offers a spacious interior, capable of accommodating large loads. Its flexible rack system includes adjustable tines and folding platforms, making it easy to fit various dish sizes, from pots and pans to delicate glassware. Additionally, the third rack feature provides extra space for utensils and smaller items, enhancing its capacity and versatility.

In terms of cleaning power, the D9412GV3 is equipped with the PrecisionWash system. This cutting-edge technology features intelligent sensors that continuously scan and check the load, adjusting the wash cycle as needed for optimal results. Coupled with the 40 dBA noise level, it ensures that the dishwasher operates quietly in the background, so you can enjoy your home without disruptive sounds.

Another standout characteristic is the PureDry technology, an integrated drying system that uses a condensation process to gently dry dishes without the need for extra heat. This not only protects sensitive items but also saves energy, further enhancing the appliance's eco-friendly nature.

Ease of use is a priority for Bosch, as seen in the D9412GV3's user-friendly controls. The intuitive interface allows for selecting various wash cycles and options, including Heavy, Auto, and Quick options, catering to different cleaning needs. Additionally, the Time Delay feature provides the flexibility to set the dishwasher to run at a later time, great for aligning with your schedule.

In summary, the Bosch D9412GV3 combines innovative technologies with a user-centered design to deliver a top-tier dishwasher experience. Its energy-efficient operation, spacious interior, and advanced cleaning features make it an excellent choice for any kitchen, ensuring spotless dishes with minimal effort. With Bosch's commitment to quality, the D9412GV3 stands as a reliable and stylish addition to any modern home.