Bosch Appliances D9412GV3 manual RPS IP Address #, RPS Port Number, Default Selection 0.0.0.0 to

Models: D9412GV3

1 154
Download 154 pages 49.97 Kb
Page 130
Image 130

D9412GV3/D7412GV3 Program Entry Guide 5.0 AUXPARM

EN 130

RPS IP Address #

Default: 0.0.0.0

Selection: 0.0.0.0 to 255.255.255.255

0 to 255 There are four numbers for an IP address. Leading zeros are not required.

This prompt contains the IP address for RPS.

An IP address has four fields. Each field has a range of 0 to 255. For example, an IP address is expressed as 110.227.64.190. Contact your network administrator to determine the IP address to which the RPS computer is connected.

Refer to Keypad Programming of RPS IP Address # and RPS PortNumber on page 130.

RPS Port Number

Default: 7750

Selection: 1 to 65535

This prompt specifies the destination port for outgoing RPS session requests to the IP address specified in RPS IP Address #.

Keypad Programming of RPS IP Address # and RPS PortNumber

D1255

1.Refer to Figure 1 on page 7 to access Keypad Programming and navigate to the RPS PARAMETERS option. Press [ENT].The keypad shows the RPS PASSCODE option and the currently configured passcode.

2.Press [NEXT] twice to advance to the RPS IP ADDRESS option and press [ENT]. The currently configured IP address shows.

3.An invisible editing cursor is enabled for the first byte.

4.The [PREV] button acts as a [Backspace] key. Press [PREV] to delete the characters of the byte, and then enter the new byte numbers, or press [NEXT] to move to the next byte.

The keypad does not accept invalid byte numbers.

5.Repeat Step 4 to enter the correct numbers for each byte.

6.Press [ENT] to save the changes.

When the keypad reads Parameter Saved, your selection is configured.

7.When the keypad reads RPS IP ADDRESS, press [NEXT] to advance to the RPS IP PORT option. The keypad shows the currently configured port number.

8.Press [ENT] to change the port number.

9.The [PREV] button acts as a [Backspace] key. Press [PREV] to delete the characters of the port number and then enter the new port number.

10.Press [ENT] to save the changes.

When the keypad reads PARAMETER SAVED, your selection is configured.

D1260

1.Refer to Figure 2 on page 8 to access Keypad Programming and navigate to the RPS Parameters option. Press [ENT].The keypad shows the RPS Passcode option and the currently configured passcode.

2.Press Phone Number softkey. The keypad shows the currently configured phone number and the IP Address option.

3.Press the IP Address softkey. The currently configured IP address shows.

4.Press the Edit softkey to change the IP address.

5.The Previous and Next softkeys move the cursor through the bytes. The Backspace softkey allows you to erase characters. The Clear softkey allows you to clear the entire IP address. Use the softkeys and the number buttons on the keypad to enter the new IP Address.

The keypad does not accept invalid byte numbers.

6. Press the Save softkey to save the changes.

When the keypad reads Parameter Saved, your selection is configured.

7.When the keypad reads RPS IP Address, press the Port Number softkey. The keypad shows the currently configured port number.

8.Press the Edit softkey to change the port number.

9.The Backspace softkey allows you to erase characters. The Clear softkey allows you to clear the entire port number. Use the softkeys and the number buttons on the keypad to enter the new port number.

10.Press the Exit softkey to save the changes.

Bosch Security Systems, Inc. 10/11 F01U170807-02