D9412GV3/D7412GV3 Program Entry Guide 4.0 Schedules (Skeds)

EN 107

W# Open Window Start

Default:

00: 00

Selection:

HH:MM (hours and minutes)

 

 

Enter the time you want the control panel to start the Opening Window. The window goes into effect at the beginning of the minute.

Make time entries using a 24-hour clock. For example:

Midnight is entered as 00:00 7:00 AM is entered as 07:00 2:45 PM is entered as 14:45 11:59 PM is entered as 23:59

This program item is one of three required to create an Opening Window. To program an Opening Window, Open Early Begin and Open Window Stop must also be programmed. Refer to the W# Open Early Begin prompt on page 106 for explanations of report features.

W# Open Window Stop

Default:

00: 00

Selection:

HH:MM (hours and minutes)

 

 

Enter the time you want the control panel to end the Opening Window. The window stops at the end of the minute.

Make time entries using a 24-hour clock. For example:

Midnight is entered as 00:00 7:00 AM is entered as 07:00 2:45 PM is entered as 14:45 11:59 PM is entered as 23:59

This program item is one of three required to create an Opening Window. To program an Opening Window, Open Early Begin and Open Window Start must also be programmed.

If the area is not disarmed by the time the Open Window Stop time expires, the control panel generates a Fail to Open Report if A# Fail to Open is enabled in Area-Wide Parameters.

Opening Reports generated between the Open Window Start time and Open Window Stop time can be suppressed by programming A# Disable O/C in Window as Yes. Refer to the W# Open Early Begin prompt on page 106 for additional explanations of report features.

Do not use a time of 23:59 as a window stop time unless another window begins on the next day at 00:00.

Fail to Open Reports are not sent for windows that stop at 23:59.

Figure 5: Example Opening Window Timeline (using two Opening Windows on same day)

1

2

3

4

5

6

7

8

9

1 - Areas disarmed between midnight and 6 AM

6 - Areas that are disarmed between 1 PM and 2

generate Opening Reports.

PM generate Early to Open Reports.

2 - Areas disarmed between 6 AM and 7 AM

7 - If the area is disarmed between 2 PM and 3

generate Early to Open Reports.

PM regular Opening Reports are generated. If

3 - If the area is disarmed between 7 AM and 8 AM

Disable O/C in Window is programmed Yes,

regular Opening Reports are generated. If

the Opening Report is not transmitted to the

Disable O/C in Window is programmed Yes the

central station.

Opening Report is not sent to the central station.

8 - If the area is not disarmed by 3:01 PM, a Fail to

4 - If the area is not disarmed by 8:01 AM, a Fail to

Open Event is generated if Fail to Open is

Open Event is generated if Fail to Open is

programmed Yes in Opening and Closing

programmed Yes in Opening and Closing

Options.

Options.

9 - If the user disarms the area between 3:01 PM

5 - If the user disarms the area between 8:01 AM

and 11:59 PM, a Late to Open Event is

and 12:59, PM a Late to Open Event is

generated.

generated.

 

Bosch Security Systems, Inc. 10/11 F01U170807-02

Page 107
Image 107
Bosch Appliances D9412GV3 manual # Open Window Start, # Open Window Stop, Default Selection Hhmm hours and minutes

D9412GV3 specifications

The Bosch Appliances D9412GV3 is a perfect blend of functionality and innovation, designed to meet the needs of modern households. This dishwasher is part of Bosch's reputation for creating high-quality, energy-efficient home appliances. With a sleek design and advanced technology, the D9412GV3 stands out in the crowded market of dishwashers.

One of the main features of the D9412GV3 is its remarkable efficiency. With an Energy Star rating, this model is designed to minimize water and energy consumption while still delivering exceptional cleaning performance. The EcoSense technology optimizes water usage, ensuring every wash cycle is both effective and economical, making it a responsible choice for energy-conscious consumers.

The dishwasher offers a spacious interior, capable of accommodating large loads. Its flexible rack system includes adjustable tines and folding platforms, making it easy to fit various dish sizes, from pots and pans to delicate glassware. Additionally, the third rack feature provides extra space for utensils and smaller items, enhancing its capacity and versatility.

In terms of cleaning power, the D9412GV3 is equipped with the PrecisionWash system. This cutting-edge technology features intelligent sensors that continuously scan and check the load, adjusting the wash cycle as needed for optimal results. Coupled with the 40 dBA noise level, it ensures that the dishwasher operates quietly in the background, so you can enjoy your home without disruptive sounds.

Another standout characteristic is the PureDry technology, an integrated drying system that uses a condensation process to gently dry dishes without the need for extra heat. This not only protects sensitive items but also saves energy, further enhancing the appliance's eco-friendly nature.

Ease of use is a priority for Bosch, as seen in the D9412GV3's user-friendly controls. The intuitive interface allows for selecting various wash cycles and options, including Heavy, Auto, and Quick options, catering to different cleaning needs. Additionally, the Time Delay feature provides the flexibility to set the dishwasher to run at a later time, great for aligning with your schedule.

In summary, the Bosch D9412GV3 combines innovative technologies with a user-centered design to deliver a top-tier dishwasher experience. Its energy-efficient operation, spacious interior, and advanced cleaning features make it an excellent choice for any kitchen, ensuring spotless dishes with minimal effort. With Bosch's commitment to quality, the D9412GV3 stands as a reliable and stylish addition to any modern home.