EN 5
4.0 Understanding the Text and LED Keypads
DS7447E/DS7447V2 are
16)represent the first 16 zones of the system. Both display information about control panel functions. A
The front of your keypad might look different than the keypads shown below. The instructions in this document still apply as the functions are the same.
(For other keypad operations, refer to Section 11.0 The Master Keypad on page 31.)
Figure 1: Text and LED Keypads |
|
|
| ||||||||||
Armed | Perimeter |
|
|
|
|
|
|
|
| Armed |
|
|
|
Status | Supervisory | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | Status |
|
|
|
Power | Bell Silenced | Power |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Fire | Trouble | 9 | 10 11 12 13 14 15 16 | Fire | TEST WEEKLY |
|
| ||||||
|
|
|
|
|
|
|
|
| On |
|
| On | |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| 1 |
| 2 |
|
| 3 |
| Off | 1 | 2 | 3 | Off |
|
| 4 |
| 5 |
|
| 6 |
| Perimeter | 4 | 5 | 6 | Perimeter |
|
|
|
|
|
| Only | Only | ||||||
|
| 7 |
| 8 |
|
| 9 |
| No | 7 | 8 | 9 | No |
|
|
|
|
|
| Entry | Entry | ||||||
|
| * |
| 0 |
|
| # |
| Bypass | * | 0 | # | Bypass |
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| System |
|
|
| System |
|
|
|
|
|
|
|
|
| Reset |
|
|
| Reset |
| LED Keypad |
|
| Text Keypad |
|
Table 1: | Keypad LEDs |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LED |
| Off |
| Flashing | On | |||
|
|
|
|
|
|
|
|
|
Armed |
| All areas are disarmed. |
| One or more areas are armed, or | All partitions are armed, and no alarms | |||
(red) |
|
|
|
| an alarm occurred. | occurred. | ||
Status |
| Not ready to arm (if the Armed LED |
| One or more zones are | All areas are ready to arm. | |||
(green) |
| is on, all areas are armed). |
| bypassed. |
|
| ||
|
|
|
|
|
|
|
|
|
Power |
| The control panel has lost all |
| Control panel problems exist. | Normal Operation. The control panel is | |||
(green) |
| power; no AC or battery. |
| Refer to Section 9.0 Error | running on AC power with no problems. | |||
|
|
|
|
| Displays. |
|
| |
Fire |
| There are no fire alarms. |
| A fire zone is in alarm. | A fire trouble condition exists. | |||
(red) |
|
|
|
|
|
|
|
|
These status LEDs are present only on the LED Keypad: |
|
| ||||||
|
|
|
|
|
|
| ||
Table 2: | Status LEDs |
|
|
|
| |||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
LED |
| Off |
| Flashing |
| On | ||
|
|
|
|
|
|
| ||
Perimeter |
| Control panel is disarmed or is not | This LED does not flash. |
| The perimeter is armed. | |||
(yellow) |
| perimeter armed. |
|
|
|
| ||
Supervisory | There are no supervisory alarms |
| A supervisory condition exists. |
| This LED does not turn on steady. | |||
(yellow) |
| present. |
|
|
|
| ||
|
|
|
|
|
|
| ||
Bell |
| The bells do not have to be or are |
| This LED does not flash. |
| There was a fire alarm and the bells | ||
Silenced |
| not silenced. |
|
|
| were silenced. To clear, enter the Fire | ||
(red) |
|
|
|
|
|
| Reset command: [PIN][System Reset] | |
Trouble |
| There are no trouble conditions. |
| This LED does not flash. |
| A trouble condition exists. | ||
(yellow) |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
LEDs 1 to |
| There are no zone alarms. |
| A zone (1 to 16) is alarmed. |
| A zone (1 to 16) is not ready to arm, | ||
16 (red) |
|
|
|
|
|
| or if a fire zone, a trouble exists. |
Volume Control
You can adjust the keypad sounder volume using the [1] and [4] keys with the [*] key.
Hold the [*] key and press the [1] key to increase the volume or the [4] key to decrease the volume.
Backlight Control (Text Keypad Only)
You can adjust the display backlight intensity using the [3] and [6] keys with the [*] key.
Hold the [*] key and press the [3] key to increase the brightness or the [6] key to decrease the brightness.
After adjusting the backlight and volume, you must arm and disarm the system once to store this information in the control panel.
If power is disconnected before the control panel is armed, the backlight and volume levels return to the default settings.
Bosch Security Systems 6/05 4998154961B