Bosch Appliances DS7400XIV4-EXP 6.2Optional Operations, 6.2.1Quick Arming, 6.2.2Force Arming, En

Models: DS7400XIV4-EXP

1 40
Download 40 pages 63.77 Kb
Page 13
Image 13
6.2Optional Operations

DS7400XiV4-EXP User Guide 6.0 Day to Day Operations

EN 13

6.2Optional Operations

6.2.1Quick Arming

Quick arming allows you to enter some arming commands without first entering a PIN. If quick arming is not used, you must enter a PIN at the beginning of all arming command sequences.

Quick arming is not available from a Master keypad or from RF (wireless) keypads.

The following shortcuts are allowed when the system is programmed for quick arming:

Table 9: Quick Arming

 

 

Type of Arming

Quick Arming Command Sequence

 

 

Normal Arming

[#][On]

Perimeter Instant Arming – no entry delay

[#][No Entry][Perimeter Only]

 

 

Perimeter Arming – entry/exit delay in effect

[#][Perimeter Only]

Maximum Security Arming

[#][No Entry][On]

 

 

6.2.2Force Arming

When one or more zones are faulted (for example, if a window or door is open), the system can be force armed (if programmed) by bypassing the faulted zones. When a text keypad displays “Not Ready” and the zone LED(s) on an LED keypad for the faulted zone(s) are lit, force arming is required to arm the system. Although an RF3341 keypad does not indicate a faulted state on the system, you can force arm the system from an RF3341 keypad. You can also force arm an area using a master keypad in Single Partition Mode.

Force Arming during an AC power failure: Regular arming of the control panel is not permitted during an AC power failure. The requirement to force arm serves as a warning that the control panel is operating under backup battery.

Bypassing or force arming removes some of your building’s protection because it excludes the faulted zones from arming. Therefore, an intrusion might not be detected or the detection might be delayed. Always attempt to correct any zone problems (close doors and windows, etc.) before using these features. If you cannot correct the problem, contact your installing company.

Table 10: Force Arming

 

 

 

 

Equipment

Command Sequence

What Happens

What To Do

 

 

 

 

Text Keypad LED

Enter any Arming

• The red Armed LED flashes during the

If leaving, exit during the exit-

Keypad

Command Sequence.

exit-delay period.

delay period.

 

Enter [Bypass] during the

• All zones normally armed by the

 

 

five-second beep.

Arming Command Sequence are

 

 

 

armed except for the faulted zones.

 

RF3341 Keypad

Any Arming Command

• The LED flashes indicating a signal

If leaving, exit during the exit-

 

Sequence [9]

was sent to your security system.

delay period.

 

 

• All zones normally armed by the

 

 

 

Arming Command Sequence are

 

 

 

armed except for the faulted zones.

 

RF3332/RF3332E,

 

Not applicable

 

RF3334/RF3334E

 

 

 

* Text Keypad only

 

 

 

Bosch Security Systems 6/05 4998154961B

Page 13
Image 13
Bosch Appliances DS7400XIV4-EXP manual 6.2Optional Operations, 6.2.1Quick Arming, 6.2.2Force Arming, En