DS7400XiV4-EXP User Guide 10.0

Testing Your System

 

 

EN 27

10.0Testing Your System

10.1Zone Test

The zone test confirms that detectors report alarms to the keypad. A zone test works on all zones, except 24-hour zones and fire zones. While the keypad is in a zone test, no control panel alarms activate an alarm, except 24-hour zone alarms and fire alarms; these alarms override the zone test function.

This test requires you to manually alarm each zone.

At the start of the test, if programmed, a report is sent to the central station followed by reports on the individual zones as they are tested. When the zone test is complete, a test restoral report is sent to the central station.

If you perform this test from a Master Keypad, the keypad must be in Single Partition Mode. Zone tests are not available from RF (wireless) keypads.

Test the system weekly.

Table 25: Zone Test

 

 

 

 

Type of Test

Command Sequence

What Happens

What To Do

 

 

 

 

Zone Test

[PIN][#][8][1]

• “Test Zone” is displayed followed by the

• Test each zone as

 

 

numbers of the zones that were not tested. *

instructed by your

 

 

• The zone LEDs of any untested zones flash. **

installing company.

 

 

• “Now Testing” is displayed followed by the

• Exit the Zone Test using

 

 

number of the zone currently being tested. *

[PIN][#].

 

 

• The LED for the zone currently being tested

 

 

 

turns on steady. **

 

 

 

• As each zone is tested, “Test Zone” appears

 

 

 

followed by the remaining untested zones. *

 

 

 

• As each zone is tested, its LED turns off. **

 

 

 

 

 

*Text Keypad only ** LED Keypad only

Bosch Security Systems 6/05 4998154961B

Page 27
Image 27
Bosch Appliances DS7400XIV4-EXP manual Testing Your System, Test the system weekly Zone Test