8.4PIN Authority Levels
0 = Master
Can enter all commands, add or change PINs in assigned areas, change the time and date, bypass, arm, disarm, perform system tests, system reset, and view history. User Number 001 must have the Master authority level. Any or all PINs can behave as a Master code. The Master code always has authority in all partitions.
1 = Unlimited
Can enter all commands, bypass, arm, disarm, system reset, and perform system tests. It cannot change PINs.
2 = General
Can bypass, arm, and disarm. It cannot change PINs, system reset, enter [#][7], or any of the [#][8] functions.
3 = Arm Only
Can arm the system with [PIN][ON] arming sequence only. Cannot perform other functions, including disarming.
4 = Temporary
Valid only for a specified time (the PIN expires on a
5 = Duress
When the system is disarmed using the duress code, a silent report is sent to your monitoring service. The duress code is intended to be used when the user is forced to disarm the system. Refer to Section 7.10 Turning OFF (Disarming) Your System under Duress on page 22.
6 = Access Code
When a PIN with an access code is entered, any output programmed for access output (for example, door strikes) pulse on for 10 seconds (works when the system is armed or disarmed).
8.5Changing the Expiration Date for Temporary PINs
Since you can only change the expiration date for temporary PINs in Master Programming Mode, they are not programmable from an RF (wireless) keypad. Do this procedure at a text keypad because no visual clues are provided by an LED keypad.
Record your entries so they are available before you enter Master Programming Mode. Enter the parameters promptly. If a delay of 15 seconds or more occurs between entries, the
Table 22: Changing the Expiration Date
|
|
|
|
Steps To Change the Expiration Date | Command Sequence | If Accepted, the Text Keypad Display Reads: | |
|
|
|
|
Enter Master Programming Mode. | [Master PIN][#][0] | “3 Change Date of Code Expiration” * | |
|
|
| (display scrolls to this) |
Enter 3 for Date of Code Expiration Setup | [3] |
| “Enter Month” |
programming. |
|
| (01 ... 12) |
Enter the Expiration Month. | [0][1] through [1][2] | “Enter Day” | |
| January | December | (01 ... 31) |
Enter the Expiration Day. The temporary PIN | [0][1] through [3][1] | “Enter Year” | |
expires at midnight on the day selected. |
|
| (XX) End with # |
|
|
|
|
Enter the Year. | Last two digits of the year | “Month, Day, Year” | |
| followed by [#] | A long beep signifies acceptance. |
*Appears only when in Single Partition Mode. Note: Enter the command sequence [Master Code][#][3][#] to cause the text keypad to display the temporary code expiration date.