DCN Next Generation Multi Voting
en 34
Identification
DCNNG RESULT x.0<SEP>voting number<SEP>voting name<SEP>voting subject<SEP>voting kind<SEP>number of answers<EOL>
where:
DCNNG RESULT x.0 | Indicates the type of file and the version of DCN Next |
| Generation that produced it. In this file type indication, the letter |
| ‘x’ represents the major version number of the DCN Next |
voting number | Generation software. |
A number in the range | |
voting name | The name of the vote. |
voting subject | The voting subject text. |
voting kind | A number in the range |
number of answers | table 1 for explanation. |
The number of possible answer options in this vote. |
Answer legend
This line is repeated ‘number of answers’ times:
answer legend<SEP>answer text<SEP>answer correct<EOL>
where: |
|
answer legend | Legend text for the answer. |
answer text | Descriptive text for the answer. |
answer correct | In a multiple choice vote, this setting indicates whether the |
| answer is correct (TRUE) or incorrect (FALSE). |
Date and time
This line contains the date and time the voting was performed (the exact time will indicate the time the voting is stopped).
where: |
|
Date of voting, DD = day (2 digits), MM = month (2 digits), | |
HH:MM | YYYY = year (4 digits). |
Time of voting, HH = hour (2 digits, 24 hour military time | |
| format), MM = minutes (2 digits) |
Total results
total voting results<EOL>
present legend<SEP>number of present<EOL> not voted legend<SEP>number of not voted<EOL>
quorum name<SEP>required quorum<SEP>authorized delegates<EOL> majority name<SEP>required majority<SEP>majority<EOL>
where: |
|
total voting results | The average result |
present legend | type voting. |
Legend text | |
number of present | The number of voters registered as present |
not voted legend | Legend text |
number of not voted | The number of present voters who have not voted |
quorum name | The name of the used Quorum formula |
required quorum | The number of authorized delegates that must be present for a |
| voting to become approved, it will be 65535 (0xFFFF) when no |
authorized delegates | quorum is required |
The number of authorized delegates present | |
majority name | The name of the used Majority formula |
required majority | The number of “for”- or |
| become approved, it will be 4294967295 (0xFFFFFFFF) when no |
Majority | majority is required) |
The number of “for”- or |
Bosch Security Systems B.V. 2005 September 9922 141 70392