Functions continued | English |
|
|
3.4Contact assignment
PIN | Function | Electrical specification |
|
|
|
1 | Input contact I | Internal |
| Open: sensor armed |
|
| At ground (Pin 5): Sensor disarmed |
|
|
|
|
2 | Input contact II | Internal |
| Open: Parameter set I active |
|
| At ground (Pin 5): |
|
| Parameter set II active |
|
|
|
|
3 | Output contact I | Open collector, |
| Internally switched to ground: Object detected | max. 100mA, 12V |
| Open: No object detected | Externally switchable |
| (constant signal, impulse or periodic impulse) |
|
|
|
|
4 | Output contact II | Open collector, |
| Internally switched to ground: | max. 100mA, 12V |
| Video signal malfunction | Externally switchable |
| Open: Video signal OK |
|
|
|
|
5 | Ground |
|
6 | Relay I | Max. 30V, max. 1A |
| 6/7 closed: Malfunction |
|
|
|
|
7 | Relay I (Middle contact) | Max. 30V, max. 1A |
|
|
|
8 | Relay I | Max. 30V, max. 1A |
| 8/7 closed: No malfunction |
|
|
|
|
9 | Relay II | Max. 30V, max. 1A |
| 9/10 closed: No alarm |
|
|
|
|
10 | Relay II (Middle contact) | Max. 30V, max. 1A |
|
|
|
11 | Relay II | Max. 30V, max. 1A |
| 11/10 closed: Alarm |
|
|
|
|
12 | Remote control Rotary switch: | Internal |
| Backwards in alarm archive |
|
|
|
|
13 | Remote control Rotary switch: | Internal |
| – Switchover: Live image/alarm archive |
|
| – active >2 secs. = alarm acknowledgement |
|
|
|
|
14 | Remote control Rotary switch: | Internal |
| Forwards in alarm archive |
|
|
|
|
15 | Remote control Rotary switch: Ground |
|
|
|
|
Input contacts
Remote control
1/2
12/13/14
+5V
Output contacts | 3/4 |
–
5/15
5/15
– 9 – | A1 February 03/Trb |