3.4Contact assignment

PIN

Function

Electrical specification

 

 

 

1

Input contact I

Internal pull-up

 

Open: sensor armed

 

 

At ground (Pin 5): Sensor disarmed

 

 

 

 

2

Input contact II

Internal pull-up

 

Open: Parameter set I active

 

 

At ground (Pin 5):

 

 

Parameter set II active

 

 

 

 

3

Output contact I

Open collector,

 

Internally switched to ground: Object detected

max. 100mA, 12V

 

Open: No object detected

Externally switchable

 

(constant signal, impulse or periodic impulse)

 

 

 

 

4

Output contact II

Open collector,

 

Internally switched to ground:

max. 100mA, 12V

 

Video signal malfunction

Externally switchable

 

Open: Video signal OK

 

 

 

 

5

Ground

 

6

Relay I

Max. 30V, max. 1A

 

6/7 closed: Malfunction

 

 

 

 

7

Relay I (Middle contact)

Max. 30V, max. 1A

 

 

 

8

Relay I

Max. 30V, max. 1A

 

8/7 closed: No malfunction

 

 

 

 

9

Relay II

Max. 30V, max. 1A

 

9/10 closed: No alarm

 

 

 

 

10

Relay II (Middle contact)

Max. 30V, max. 1A

 

 

 

11

Relay II

Max. 30V, max. 1A

 

11/10 closed: Alarm

 

 

 

 

12

Remote control Rotary switch:

Internal pull-up

 

Backwards in alarm archive (–) when turned left

 

 

 

 

13

Remote control Rotary switch:

Internal pull-up

 

– Switchover: Live image/alarm archive

 

 

– active >2 secs. = alarm acknowledgement

 

 

 

 

14

Remote control Rotary switch:

Internal pull-up

 

Forwards in alarm archive (–) when turned right

 

 

 

 

15

Remote control Rotary switch: Ground

 

 

 

 

Input contacts

Remote control

1/2

12/13/14

+5V

Output contacts

3/4

5/15

5/15

– 9 –

A1 February 03/Trb

Page 9
Image 9
Bosch Appliances VMD01 M50 PAL, VMD01 M60 NTSC manual Contact assignment