Bosch Appliances X10 Maintenance and Upgrades, Testing the Network Connection, 7.2Unit Reset

Models: X10

1 124
Download 124 pages 61 Kb
Page 101
Image 101
Maintenance and Upgrades

VideoJet X10Maintenance and Upgrades en 101

7

Maintenance and Upgrades

7.1

Testing the Network Connection

You can use the ping command to check the connection between two IP addresses. This allows you to test whether a unit in the network is active.

1.Open the DOS command prompt.

2.Type ping followed by the IP address of the unit.

If the unit is found, the response appears as Reply from ... followed by the number of bytes sent and the transmission time in milliseconds. If not, the unit cannot be accessed over the network. This might be because:

The unit is not correctly connected to the network. Check the cable connections in this case.

The unit is not correctly integrated into the network. Check the IP address, subnet mask and gateway address.

7.2Unit Reset

You can use the Factory Reset button to restore the unit to its original settings. Any changes to the settings are overwritten by the factory defaults. A reset may be necessary, for example, if the unit has invalid settings that prevent it from functioning as desired.

CAUTION!

!All configured settings will be discarded during a reset.

If necessary, back up the current configuration using the Download button on the Maintenance configuration page (see Section 5.43 Advanced Mode: Maintenance, page 84).

NOTICE!

i

After a reset, the unit can only be addressed via the factory default IP address. The IP address

 

 

can be changed as described in the Installation chapter (see Section 4.5 Setup Using the

 

Configuration Manager, page 25).

 

 

1.If necessary, back up the current configuration using the Download button on the Maintenance configuration page (see Section 5.43 Advanced Mode: Maintenance, page 84).

2.Using a pointed object, press the Factory Reset button located below the orange terminal block until the Connect LED flashes red (see Section 3.4 Connections on the Front Panel, page 16). All settings will revert to their defaults.

3.Change the IP address of the VideoJet X10 if necessary.

4.Configure the unit to meet your requirements.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Page 101
Image 101
Bosch Appliances X10 Maintenance and Upgrades, Testing the Network Connection, 7.2Unit Reset, Configuration Manager, page