Bosch Appliances X10 manual 8.5Processor Load, Network Connection, 8.7Serial Interface

Models: X10

1 124
Download 124 pages 61 Kb
Page 108
Image 108
8.5Processor Load

108 en AppendixVideoJet X10

8.5Processor Load

If the VideoJet X10 is accessed via the Web browser, you will see the processor load indicator in the top right of the window next to the manufacturer's logo.

You can obtain additional information to help you when troubleshooting or fine tuning the unit. The values indicate the proportions of the individual functions on the encoder load, shown as percentages. The JPEG parameter relates to snapshots and M-JPEG. The scaler converts the input format 4CIF to the other formats configured.

1.Move the cursor over the graphic indicator. Some additional numerical values are also displayed.

2.Click the graphic indicator. Further details are displayed.

8.6

Network Connection

You can display information about the network connection. To do this, move the cursor over the i icon.

Link

Ethernet link type

UL

Uplink, speed of the outgoing data traffic

DL

Downlink, speed of the incoming data traffic

8.7Serial Interface

Options for using the serial interface include transferring transparent data, controlling connected units or operating the unit with a terminal program.

The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. The mode used depends on the current configuration (see Section 5.37 Advanced Mode: COM1, page 76). Connection is via the terminal block.

DOC V4.0 2009.06

Installation and Operating Manual

Bosch Security Systems

Page 108
Image 108
Bosch Appliances X10 manual 8.5Processor Load, Network Connection, 8.7Serial Interface