Operating mode

VideoJet X10

Configuration Using a Web Browser en 75

 

 

Operating mode

Select an operating mode for the relay.

For example, if you want an alarm-activated lamp to stay on after the alarm ends, select Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select

10 s.

Relay follows

If required, select a specific event that will trigger the relay. The following events are possible triggers:

Off

Relay is not triggered by events

Connection

Trigger whenever a connection is made

Video alarm

Trigger by interruption of the video signal

Motion alarm

Trigger by motion alarm, as configured on the VCA page (see Section 5.31 Advanced Mode: VCA Event Triggered, page 69)

Local input

Trigger by the corresponding external alarm input

Remote input

Trigger by remote station's corresponding switching contact (only if a connection exists)

NOTICE!

i The numbers in the lists of selectable events relate to the corresponding connections on the unit, Video alarm 1, for example to the Video In connection.

Relay name

You can assign a name for the relay here. The name is shown on the button next to Trigger relay. The Livepage can also be configured to display the name under the relay icon.

Trigger relay

Click the button to trigger the relay manually (for testing or to operate a door opener, for example).