Malfunctions with iSCSI Connections

106 en AppendixVideoJet X10

8.3

Malfunctions with iSCSI Connections

 

 

 

 

 

 

 

 

Malfunction

Possible causes

Recommended solution

 

 

 

 

 

 

 

After connecting to the

Incorrect LUN mapping during

Check the iSCSI system

 

 

iSCSI destination, no

iSCSI system configuration.

configuration and reconnect.

 

 

LUNs are displayed.

 

 

 

 

 

 

 

 

 

After connecting to the

The LUN list could not be read,

Check the iSCSI system

 

 

iSCSI destination, "LUN

as it was assigned to the wrong

configuration and reconnect.

 

 

FAIL" appears below a

network interface.

 

 

 

node.

 

 

 

 

 

 

 

 

 

LUN mapping is not

Some iSCSI systems do not

Delete the initiator extension on

 

 

possible.

support the use of an initiator

the Identification configuration

 

 

 

extension.

page.

 

 

 

 

 