A Environmental considerations

Environmental considerations

Table 4 lists the acceptable environmental ranges for both operating and nonoperating (such as during transportation or storage) conditions.

TABLE 4

Environmental requirements

 

 

 

 

Condition

Acceptable during operation

Acceptable during non-operation

 

 

 

Ambient

0º to 40ºC (32º to 104ºF)

-25º to 70ºC (-23º to 158ºF)

Temperature

 

 

 

 

 

Humidity

10% to 95% RH non-condensing, at

5% to 80% RH non-condensing, at 70ºC

 

40ºC (104ºF)

(158ºF)

 

 

 

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea level

 

 

 

Shock

20 G, 6 ms, half-sine wave

33 G, 11 ms, half-sine wave, 3/eg Axis

 

 

 

Vibration

0.5 G sine, 0.4 gms random, 5-500 Hz

2.0 G sine, 1.1 gms random, 5-500 Hz

 

 

 

Airflow

Maximum - 90.1 cmh (53 cfm)

N/A

 

Nominal - 59.5 cmh (35 cfm)

 

 

 

 

Heat

478 BTU/hr

N/A

dissipation

 

 

 

 

 

Operating

46.7 dB

N/A

noise

 

 

 

 

 

Cooling system and fans

Fans cool the CPU, main memory, and voltage regulators. For Brocade ICX 6650 switches, the fans use either:

An exhaust airflow which moves air from front to back. See Figure 19. Devices with exhaust airflow are labeled with a green arrow with “E.” See Figure 20.

An intake airflow which moves air from back to front. See Figure 21. Devices with intake airflow are labeled with an orange arrow with “I.” See Figure 22.

CAUTION

Be sure that the airflow direction of the power supply unit matches that of the installed fan tray. The power supplies and fan trays are clearly labeled with either a green arrow with an “E” for exhaust, or an orange arrow with an “I” for intake.