A Environmental considerations
Environmental considerations
Table 4 lists the acceptable environmental ranges for both operating and nonoperating (such as during transportation or storage) conditions.
TABLE 4 | Environmental requirements |
|
|
|
|
Condition | Acceptable during operation | Acceptable during |
|
|
|
Ambient | 0º to 40ºC (32º to 104ºF) | |
Temperature |
|
|
|
|
|
Humidity | 10% to 95% RH | 5% to 80% RH |
| 40ºC (104ºF) | (158ºF) |
|
|
|
Altitude | 0 to 3 km (9,842 feet) above sea level | 0 to 12 km (39,370 feet) above sea level |
|
|
|
Shock | 20 G, 6 ms, | 33 G, 11 ms, |
|
|
|
Vibration | 0.5 G sine, 0.4 gms random, | 2.0 G sine, 1.1 gms random, |
|
|
|
Airflow | Maximum - 90.1 cmh (53 cfm) | N/A |
| Nominal - 59.5 cmh (35 cfm) |
|
|
|
|
Heat | 478 BTU/hr | N/A |
dissipation |
|
|
|
|
|
Operating | 46.7 dB | N/A |
noise |
|
|
|
|
|
Cooling system and fans
Fans cool the CPU, main memory, and voltage regulators. For Brocade ICX 6650 switches, the fans use either:
•An exhaust airflow which moves air from front to back. See Figure 19. Devices with exhaust airflow are labeled with a green arrow with “E.” See Figure 20.
•An intake airflow which moves air from back to front. See Figure 21. Devices with intake airflow are labeled with an orange arrow with “I.” See Figure 22.
CAUTION
Be sure that the airflow direction of the power supply unit matches that of the installed fan tray. The power supplies and fan trays are clearly labeled with either a green arrow with an “E” for exhaust, or an orange arrow with an “I” for intake.
46 | Brocade ICX 6650 Hardware Installation Guide |
|