4 LED patterns

LED patterns

The following sections describe the Brocade ICX 6650 LED patterns.

PSU 1 and PSU2

LED State

Status of hardware

Recommended action

Off (no light)

System is off or there is no power.

Verify the system is on and has

 

 

completed booting.

Steady green

PSU is on and functioning properly.

No action required.

Steady amber

PSU is in faulty state or missing power.

Replace power supply.

DIAG LED

LED State

Status of hardware

Recommended action

Off (no light)

Diagnostic is off.

No action required.

Blinking green

System self-diagnostic test is in progress.

No action required.

Steady green

System self-diagnostic test is successfully

No action required.

 

completed. Device reboot and clears back to off.

 

Steady amber

System self-diagnostic test has detected a fault. Contact support.

Management port status LED

LED State

Status of hardware

Recommended action

Off (no light)

Not cabled.

No action required

Blinking

There is traffic and packets are being

No action required.

 

transmitted or received.

 

Steady

No traffic being transmitted, but link is up.

No action required.

1/10 GbE SFP+ port LEDs

LED State

Status of hardware

Recommended action

Green

Link is up in 10 GbE mode.

No action required.

Blinking green

There is 10 GbE activity (traffic) and packets are

No action required.

 

being transmitted or received.

 

Amber

Link is up in 1 GbE mode.

No action required.

Blinking amber

There is 1 GbE activity (traffic) and packets are

No action required.

 

being transmitted or received.

 

40 GbE GSFP+ rear port LEDs on front panel

LED State

Status of hardware

Recommended action

Off (no light)

Not enabled.

No action required.

Blue

Link is up in 40 GbE mode.

No action required.

Blinking blue

Indicates activity, and packets are being

No action required.

 

transmitted or received.

 

32

Brocade ICX 6650 Hardware Installation Guide

 

53-1002599-01

Page 48
Image 48
Brocade Communications Systems 53-1002599-01 manual LED patterns, PSU 1 and PSU2