4 LED patterns
LED patterns
The following sections describe the Brocade ICX 6650 LED patterns.
PSU 1 and PSU2
LED State | Status of hardware | Recommended action |
Off (no light) | System is off or there is no power. | Verify the system is on and has |
|
| completed booting. |
Steady green | PSU is on and functioning properly. | No action required. |
Steady amber | PSU is in faulty state or missing power. | Replace power supply. |
DIAG LED
LED State | Status of hardware | Recommended action |
Off (no light) | Diagnostic is off. | No action required. |
Blinking green | System | No action required. |
Steady green | System | No action required. |
| completed. Device reboot and clears back to off. |
|
Steady amber | System |
Management port status LED
LED State | Status of hardware | Recommended action |
Off (no light) | Not cabled. | No action required |
Blinking | There is traffic and packets are being | No action required. |
| transmitted or received. |
|
Steady | No traffic being transmitted, but link is up. | No action required. |
1/10 GbE SFP+ port LEDs
LED State | Status of hardware | Recommended action |
Green | Link is up in 10 GbE mode. | No action required. |
Blinking green | There is 10 GbE activity (traffic) and packets are | No action required. |
| being transmitted or received. |
|
Amber | Link is up in 1 GbE mode. | No action required. |
Blinking amber | There is 1 GbE activity (traffic) and packets are | No action required. |
| being transmitted or received. |
|
40 GbE GSFP+ rear port LEDs on front panel
LED State | Status of hardware | Recommended action |
Off (no light) | Not enabled. | No action required. |
Blue | Link is up in 40 GbE mode. | No action required. |
Blinking blue | Indicates activity, and packets are being | No action required. |
| transmitted or received. |
|
32 | Brocade ICX 6650 Hardware Installation Guide |
|