Appendix A: Specifications

A.3 ENVIRONMENTAL REQUIREMENTS

Operating Temperature: 5°C to 40°C (41°F to 104°F)

Storage Temperature:

-30°C to 90°C (-22°F to 194°F)

Operating Humidity:

5% to 95% (non-condensing)

A.4 CERTIFICATION

Safety:

UL 1950, CSA C22.2 No. 950, EN 60950, and

 

IEC 950

Emission:

FCC Part 15 Class A, VCCI Class I, and

 

EN 55022 Class A

Immunity:

EN 50082-1

This unit has been tested by Bellcore and found to comply with the following Bellcore standards:

TR-NWT-000063

Network Equipment Building System (NEBS)

 

Generic Equipment Requirements

GR-1098-CORE

EMC and Electrical Safety Generic Criteria for

 

Network Telecommunications Equipment

A.5 COM PORT PINOUT

Type: Standard RJ45 port

Pin

Function

Connection Attitude

 

 

 

 

 

 

1

Transmit Data (XMT)

From COM 2 port

 

 

 

2

Data Carrier Detect (DCD)

From COM 2 port

 

 

 

3

Data Set Ready (DSR)

To COM 2 port

 

 

 

4

Receive Data (RCV)

To COM 2 port

 

 

 

5

Signal Ground (GND)

NA

 

 

 

6

Data Terminal Ready (DTR)

From COM 2 port

 

 

 

7

Request to Send (RTS)

To COM 2 port

 

 

 

8

Clear to Send (CTS)

NA

 

 

 