Chapter 3: Installation
3.If the transceiver PWR LED is OFF with the AUI cable connected, perform the following steps:
a.Check the AUI connections for proper pinouts.
b.Check the cable for continuity.
c.Reconnect the AUI cable to the
If the transceiver PWR LED remains OFF, contact Cabletron Systems Technical Support.
3.5.5Connecting a 10BASE2 Segment to an EPIM-C
NOTE |
For proper operation, the
To connect a thin coaxial cable segment to an
Before attaching a male BNC connector to a female BNC barrel connector or terminator, look into the end of the connector to verify that the gold contact pin is present and centered. Any bent or broken pins may not connect properly and should be replaced.
1.Set the Internal Termination (TERM) switch, located to the right of the port and labeled TERM, to one of the following positions:
a.The ON position () to internally terminate the thin coaxial cable segment at the port. Thin coaxial cable segments may be directly connected to the port.
b.The OFF position () to not internally terminate the thin coaxial cable segment at the port. Segments may only be connected through
|